Literature DB >> 18038008

Force plate gait analysis at the walk and trot in dogs with low-grade hindlimb lameness.

K Voss1, J Imhof, S Kaestner, P M Montavon.   

Abstract

OBJECTIVE: To evaluate the accuracy of force plate gait analysis at the walk and trot in dogs with low-grade hindlimb lameness.
MATERIAL AND METHODS: Nineteen healthy dogs and 41 dogs with low-grade unilateral hindlimb lameness due to stifle or hip joint problems were walked and trotted over a force plate. Peak vertical forces (PVF) were recorded, and a symmetry index (SI) was calculated from the PVF of the hindlimbs. 'Cut-off' values were determined from the SI of the normal dogs. These cut-off values were used to discriminate lame dogs from normal ones. Sensitivity and specificity were evaluated for measurements at walk and trot, and the Cohen's Kappa coefficient (k) was used to determine the agreement between clinical lameness and force plate measurements, and between force plate results at walk and trot. Receiver Operating Characteristics (ROC) curve were plotted for both gaits to evaluate accuracy.
RESULTS: The sensitivity of the measurements at walk was 0.63, and specifity was 0.95. The sensitivity of the measurements at trot was 0.90, and specificity was 1.0. Moderate agreement was found between force plate measurements at walk and trot, and between clinical gait assessment and force plate measurements at walk. Good agreement was found between clinical gait assessment and measurements at trot. ROC analyses revealed the trot (94.7% [91.7%; 97.7%]) to be the more accurate test than the walk (85.0% [80.1%; 89.9%]).
CONCLUSION: The trotting gait was more sensitive and accurate than the walking gait for the differentiation of dogs with a low-grade hindlimb lameness from normal ones using force plate gait analysis.

Entities:  

Mesh:

Year:  2007        PMID: 18038008     DOI: 10.1160/vcot-07-01-0008

Source DB:  PubMed          Journal:  Vet Comp Orthop Traumatol        ISSN: 0932-0814            Impact factor:   1.358


  24 in total

1.  Force plate gait analysis in Doberman Pinschers with and without cervical spondylomyelopathy.

Authors:  K Foss; R C da Costa; P J Rajala-Schuttz; P J Rajala-Shultz; M J Allen
Journal:  J Vet Intern Med       Date:  2012-12-26       Impact factor: 3.333

2.  Evaluation of a novel accelerometer for kinetic gait analysis in dogs.

Authors:  Kyle Clark; Charles Caraguel; Lorne Leahey; Romain Béraud
Journal:  Can J Vet Res       Date:  2014-07       Impact factor: 1.310

3.  Variance associated with walking velocity during force platform gait analysis of a heterogeneous sample of clinically normal dogs.

Authors:  Alexander M Piazza; Emily E Binversie; Lauren A Baker; Brett Nemke; Susannah J Sample; Peter Muir
Journal:  Am J Vet Res       Date:  2017-04       Impact factor: 1.156

4.  Variance associated with subject velocity and trial repetition during force platform gait analysis in a heterogeneous population of clinically normal dogs.

Authors:  Eric C Hans; Berdien Zwarthoed; Joseph Seliski; Brett Nemke; Peter Muir
Journal:  Vet J       Date:  2014-09-28       Impact factor: 2.688

5.  Variance associated with the use of relative velocity for force platform gait analysis in a heterogeneous population of clinically normal dogs.

Authors:  Nicola Volstad; Brett Nemke; Peter Muir
Journal:  Vet J       Date:  2015-08-13       Impact factor: 2.688

6.  Biceps femoris muscle transposition for treatment of cranial cruciate ligament rupture in small breed dogs.

Authors:  Roberto Tamburro; Stefania Pinna; Anna Maria Tribuiani; Alessandra Panacea; Fabio Carli; Antonio Venturini
Journal:  J Vet Sci       Date:  2012-03       Impact factor: 1.672

7.  Gait analysis in dogs with pelvic fractures treated conservatively using a pressure-sensing walkway.

Authors:  Flávia Gardilin Vassalo; Sheila Canevese Rahal; Felipe Stefan Agostinho; Maria Jaqueline Mamprim; Alessandra Melchert; Washington Takashi Kano; Luciane dos Reis Mesquita; Danuta Pulz Doiche
Journal:  Acta Vet Scand       Date:  2015-10-05       Impact factor: 1.695

8.  Kinetic and temporospatial parameters in male and female cats walking over a pressure sensing walkway.

Authors:  Mirela R Verdugo; Sheila C Rahal; Felipe S Agostinho; Verônica M Govoni; Maria J Mamprim; Frederico O B Monteiro
Journal:  BMC Vet Res       Date:  2013-06-27       Impact factor: 2.741

9.  Effect of analgesic therapy on clinical outcome measures in a randomized controlled trial using client-owned dogs with hip osteoarthritis.

Authors:  Sarah Malek; Susannah J Sample; Zeev Schwartz; Brett Nemke; Peer B Jacobson; Elizabeth M Cozzi; Susan L Schaefer; Jason A Bleedorn; Gerianne Holzman; Peter Muir
Journal:  BMC Vet Res       Date:  2012-10-04       Impact factor: 2.741

10.  Controlled, blinded force platform analysis of the effect of intraarticular injection of autologous adipose-derived mesenchymal stem cells associated to PRGF-Endoret in osteoarthritic dogs.

Authors:  Jose M Vilar; Manuel Morales; Angelo Santana; Giuseppe Spinella; Mónica Rubio; Belen Cuervo; Ramón Cugat; Jose M Carrillo
Journal:  BMC Vet Res       Date:  2013-07-02       Impact factor: 2.741

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.