Literature DB >> 18037180

Computed tomography for excision cavity localization and 3D-treatment planning in partial breast irradiation with high-dose-rate interstitial brachytherapy.

Cynthia Aristei1, Roberto Tarducci, Isabella Palumbo, Antonella Cavalli, Francesca Corazzi, Antonio Rulli, Carlo Raymondi, Paolo Latini.   

Abstract

BACKGROUND AND
PURPOSE: When high-dose-rate brachytherapy is used for partial breast irradiation (PBI) precise pre-implant definition of planning target volume (PTV) and implant geometry is required. After implantation, accurate PTV localization, catheter reconstruction and optimization of dose distribution are needed for good PTV coverage and dose conformity. We applied image-guidance using computed tomography (CT) for pre-implant PTV definition and post-implant dosimetry.
MATERIALS AND METHODS: In 54 patients implant geometry was designed by external beam virtual simulation. A template was placed over dummy beam digitally reconstructed radiographs displaying PTV. Needle entrance and exit points were defined and marked on the patient's skin to serve as landmarks during implantation. After implantation, in 46/54 patients PTV was defined, catheters were reconstructed and active lengths in the catheters were specified using CT-based-3D planning system. Dosimetry was performed with a Plato-Nucletron treatment planning system.
RESULTS: Post-implantation CT visualized precise catheter placement with respect to the PTV in all patients. CT-based treatment planning provided good coverage of PTV and homogeneous dose distribution.
CONCLUSIONS: In post-operative PBI with high-dose-rate brachytherapy CT-based pre-implant definition of implant geometry ensures adequate PTV coverage. After implantation, CT-based 3D-treatment planning software ensures exact PTV localization and catheter reconstruction, and dose distribution optimization.

Entities:  

Mesh:

Year:  2007        PMID: 18037180     DOI: 10.1016/j.radonc.2007.10.029

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  4 in total

1.  Accelerated partial breast irradiation using multicatheter brachytherapy for select early-stage breast cancer: local control and toxicity.

Authors:  Seung-Gu Yeo; Juree Kim; Geum-Hee Kwak; Ji-Young Kim; Kyeongmee Park; Eun Seok Kim; Sehwan Han
Journal:  Radiat Oncol       Date:  2010-06-19       Impact factor: 3.481

2.  Three dimensional (3D) CT reconstruction in cancer imaging.

Authors:  V Rangarajan
Journal:  Indian J Med Res       Date:  2013-01       Impact factor: 2.375

Review 3.  Accelerated partial breast irradiation with brachytherapy: patient selection and technique considerations.

Authors:  Daniel M Trifiletti; Kara D Romano; Shayna L Showalter; Kelli A Reardon; Bruce Libby; Timothy N Showalter
Journal:  Breast Cancer (Dove Med Press)       Date:  2015-07-29

4.  Transition from Paris dosimetry system to 3D image-guided planning in interstitial breast brachytherapy.

Authors:  Judyta Wiercińska; Anna Wronczewska; Renata Kabacińska; Roman Makarewicz
Journal:  J Contemp Brachytherapy       Date:  2015-12-16
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.