Literature DB >> 18036962

Pre-measured artificial chordae for mitral valve repair.

A Marc Gillinov1, Michael K Banbury.   

Abstract

There is growing interest in the application of artificial chordae to correct mitral valve regurgitation caused by prolapse. Application of pre-measured artificial chordae facilitates creation of chordae of appropriate length. Herein we illustrate the technique for creation of pre-measured artificial chordae, documenting neo-chordal length and number in 50 patients with anterior leaflet prolapse, highlighting the need for chordae of more than one length in 14% of patients.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18036962     DOI: 10.1016/j.athoracsur.2007.04.046

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  8 in total

1.  Loop technique for mitral valve repair.

Authors:  Toshihiko Shibata
Journal:  Gen Thorac Cardiovasc Surg       Date:  2013-09-26

Review 2.  Different ways to repair the mitral valve with artificial chordae: a systematic review.

Authors:  Federico Bizzarri; Antonella Tudisco; Massimo Ricci; David Rose; Giacomo Frati
Journal:  J Cardiothorac Surg       Date:  2010-04-08       Impact factor: 1.637

3.  Early failure after non-resectional mitral valve repair with artificial chordae.

Authors:  Ryan A Moore; Per Wierup; Daniel J P Burns; A Marc Gillinov
Journal:  J Card Surg       Date:  2020-07-28       Impact factor: 1.620

4.  The feasibility of mitral valve device foldoplasty: an in vivo study to evaluate durable retention.

Authors:  Isaac Wamala; Mossab Y Saeed; Peter E Hammer; Daniel Bautista-Salinas; Kimberlee Gauvreau; Sunil J Ghelani; Nikolay V Vasilyev; Pedro J Del Nido
Journal:  Interact Cardiovasc Thorac Surg       Date:  2021-08-12

Review 5.  Artificial chordae for degenerative mitral valve disease: critical analysis of current techniques.

Authors:  Michael Ibrahim; Christopher Rao; Thanos Athanasiou
Journal:  Interact Cardiovasc Thorac Surg       Date:  2012-09-07

6.  Chordae replacement versus leaflet resection in minimally invasive mitral valve repair.

Authors:  Tomas Holubec; Simon H Sündermann; Stephan Jacobs; Volkmar Falk
Journal:  Ann Cardiothorac Surg       Date:  2013-11

Review 7.  Optimizing P2 Neochordal Length and Stability in Mitral Valve Repair With Use of a Polypropylene Loop.

Authors:  Anil Ozen; Ertekin Utku Unal; Hamdi Mehmet Ozbek; Gorkem Yigit; Hakki Zafer Iscan
Journal:  Tex Heart Inst J       Date:  2020-06-01

8.  Neochordameter: a new technology in mitral valve repair.

Authors:  Alireza Alizadeh-Ghavidel; Niloofar Samiei; Hoda Javadikasgari; Kamiar Bashirpour
Journal:  Res Cardiovasc Med       Date:  2013-10-28
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.