Literature DB >> 18036530

Strain shielding in proximal tibia of stemmed knee prosthesis: experimental study.

A Completo1, F Fonseca, J A Simões.   

Abstract

Theoretical concerns about the use of cemented or press-fit stems in revision total knee arthroplasty (TKA) include stress shielding with adverse effects on prosthesis fixation. Revision TKA components are commonly stemmed to protect the limited autogenous bone stock remaining. Revision procedures with the use of stems can place abnormal stresses through even normal bone by their constrained design, type of materials and fixation method and may contribute for bone loss. Experimental quantification of strain shielding in the proximal synthetic tibia following TKA is the main purpose of the present study. In this study, cortical bone strains were measured experimentally with tri-axial strain gauges in synthetic tibias before and after in vitro knee surgery. Three tibias were implanted with cemented and press-fit stem augments and solely with a tibial tray (short monobloc stem) of the P.F.C. Sigma Modular Knee System. The difference between principal strains of the implanted and the intact tibia was calculated for each strain gauge position. The results demonstrated a pronounced strain-shielding effect in the proximal level, close to tibial tray with the cemented stem augment. The press-fit stem presented a minor effect of strain shielding but was more extensively throughout the stem. An increase of strains closely to the distal tip of the cemented and the press-fit stem augment was observed. This suggests for a physiological condition, a potential effect of bone resorption at the proximal region for the cemented stem augment. The localized increase of strains in stems tip can be related with the clinical finding of the pain, at the end of stem after revision TKA.

Entities:  

Mesh:

Year:  2007        PMID: 18036530     DOI: 10.1016/j.jbiomech.2007.10.006

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  21 in total

1.  Bone mineral density changes of the proximal tibia after revision total knee arthroplasty. A randomised study with the use of porous tantalum metaphyseal cones.

Authors:  Claus L Jensen; Michael M Petersen; Henrik M Schrøder; Bjarne Lund
Journal:  Int Orthop       Date:  2012-06-26       Impact factor: 3.075

Review 2.  Fixation of revision TKA: a review of the literature.

Authors:  J Beckmann; C Lüring; R Springorum; F X Köck; J Grifka; M Tingart
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-09-07       Impact factor: 4.342

3.  The role of offset stems in revision knee arthroplasty.

Authors:  Andrea Baldini; Giovanni Balato; Vincenzo Franceschini
Journal:  Curr Rev Musculoskelet Med       Date:  2015-12

4.  Cruciate-retaining TKA using a third-generation system with a four-pegged tibial component: a minimum 10-year followup note.

Authors:  Adam J Schwartz; Craig J Della Valle; Aaron G Rosenberg; Joshua J Jacobs; Richard A Berger; Jorge O Galante
Journal:  Clin Orthop Relat Res       Date:  2010-05-04       Impact factor: 4.176

5.  Comparison between uncemented and cemented fixation for the tibial component in distal femoral replacement: a clinical and radiological study.

Authors:  Haijie Liang; Wei Guo; Rongli Yang; Xiaodong Tang; Taiqiang Yan
Journal:  Int Orthop       Date:  2018-02-24       Impact factor: 3.075

Review 6.  Fixation of stem in revision of total knee arthroplasty: cemented versus cementless-a meta-analysis.

Authors:  Changyao Wang; Tilman Pfitzner; Philipp von Roth; Hermann O Mayr; Michael Sostheim; Robert Hube
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-12-19       Impact factor: 4.342

7.  Evaluation of the rotational alignment of the tibial component in total knee arthroplasty: position prioritizing maximum coverage.

Authors:  Masashi Hirakawa; Masashi Miyazaki; Shinichi Ikeda; Yoshiki Matsumoto; Makoto Kondo; Hiroshi Tsumura
Journal:  Eur J Orthop Surg Traumatol       Date:  2016-09-10

8.  Is stemless implant fixation a valid option in total knee revision arthroplasty - Review of in vitro and in vivo studies.

Authors:  H Graichen; W Scior
Journal:  J Orthop       Date:  2021-01-05

9.  Can medio-lateral baseplate position and load sharing induce asymptomatic local bone resorption of the proximal tibia? A finite element study.

Authors:  Bernardo Innocenti; Evelyn Truyens; Luc Labey; Pius Wong; Jan Victor; Johan Bellemans
Journal:  J Orthop Surg Res       Date:  2009-07-17       Impact factor: 2.359

10.  The influence of stem length and fixation on initial femoral component stability in revision total knee replacement.

Authors:  N Conlisk; H Gray; P Pankaj; C R Howie
Journal:  Bone Joint Res       Date:  2012-11-01       Impact factor: 5.853

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.