Restoring euglycemia in the basal state using continuous glucose monitoring in subjects with type 1 diabetes mellitus.

Howard C Zisser1, Wendy C Bevier, Lois Jovanovic.   

Abstract

BACKGROUND: Our objective was to use continuous glucose monitoring to derive the optimal basal insulin infusion rates in adults with type 1 diabetes and using continuous subcutaneous insulin infusion (CSII) pumps.
METHODS: In an effort to mimic euglycemia during the basal state, we used a standard protocol to adjust basal insulin infusion rates in 16 subjects with type 1 diabetes mellitus who were using CSII pumps. All subjects wore Continuous Glucose Monitoring System sensors (CGMS), Medtronic Minimed, Northridge, CA) in order to obtain around-the-clock tracings of their glucose measurements. Subjects were asked to skip meals periodically in order to optimize basal insulin infusion rates, defined as the basal infusion rates that maintained glucose levels in the range of 65-120 mg/dL during the fasting state or between meals.
RESULTS: In order to demonstrate improved glycemic control, with blunting of glucose excursion, we compared the baseline CGMS area under the curve (AUC) to the AUC obtained after optimizing the basal insulin dosages. We analyzed the curves by determining the AUC for glucose excursions above 110 mg/dL. The AUC for glucose excursions above 110 mg/dL was significantly smaller after optimization (19 +/- 13 mg/dL.day) compared to the baseline AUC (50 +/- 31 mg/dL.day) (P < 0.001).
CONCLUSIONS: Using both a standard protocol for initial basal insulin infusion rates and CGMS curves to optimize basal infusion rates, one can improve glycemia in subjects with type 1 diabetes using CSII.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18034605     DOI: 10.1089/dia.2007.0220

Source DB:  PubMed          Journal:  Diabetes Technol Ther        ISSN: 1520-9156            Impact factor:   6.118


  6 in total

1.  Clinical update on optimal prandial insulin dosing using a refined run-to-run control algorithm.

Authors:  Howard Zisser; Cesar C Palerm; Wendy C Bevier; Francis J Doyle; Lois Jovanovic
Journal:  J Diabetes Sci Technol       Date:  2009-05-01

2.  A review of the management of implanted medical devices for diabetes: trends and directions.

Authors:  Carl Edman; Darrel Drinan
Journal:  J Diabetes Sci Technol       Date:  2008-11

3.  Use of continuous glucose monitoring to estimate insulin requirements in patients with type 1 diabetes mellitus during a short course of prednisone.

Authors:  Wendy C Bevier; Howard C Zisser; Lois Jovanovic; Daniel A Finan; Cesar C Palerm; Dale E Seborg; Francis J Doyle
Journal:  J Diabetes Sci Technol       Date:  2008-07

4.  Artificial pancreas (AP) clinical trial participants' acceptance of future AP technology.

Authors:  Wendy C Bevier; Serena M Fuller; Ryan P Fuller; Richard R Rubin; Eyal Dassau; Francis J Doyle; Lois Jovanovič; Howard C Zisser
Journal:  Diabetes Technol Ther       Date:  2014-05-08       Impact factor: 6.118

5.  A Run-to-Run Control Strategy to Adjust Basal Insulin Infusion Rates in Type 1 Diabetes.

Authors:  Cesar C Palerm; Howard Zisser; Lois Jovanovič; Francis J Doyle
Journal:  J Process Control       Date:  2008       Impact factor: 3.666

6.  Titration of Long-Acting Insulin Using Continuous Glucose Monitoring and Smart Insulin Pens in Type 1 Diabetes: A Model-Based Carbohydrate-Free Approach.

Authors:  Anas El Fathi; Chiara Fabris; Marc D Breton
Journal:  Front Endocrinol (Lausanne)       Date:  2022-01-10       Impact factor: 5.555

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.