Literature DB >> 18031751

The effect of direct measurement versus cadaver estimates of anthropometry in the calculation of joint moments during above-knee prosthetic gait in pediatrics.

Evan J Goldberg1, Philip S Requejo, Eileen G Fowler.   

Abstract

Joint reaction forces, moments and powers are important in interpreting gait mechanics and compensatory strategies used by patients walking with above-knee prostheses. Segmental anthropometrics, required to calculate joint moments, are often estimated using data from cadaver studies. However, these values may not be accurate for patients following amputation as prostheses are composed of non-biologic material. The purpose of this study was to compare joint moments using anthropometrics calculated from cadaver studies versus direct measurements of the residual limb and prosthesis for children with an above-knee amputation. Gait data were collected for four subjects with above-knee prostheses walking at preferred and fast speeds. Joint moments were computed using anthropometrics from cadaver studies and direct measurements for each subject. The difference between these two methods primarily affected the inertia couple (Ialpha term) and the inertial effect due to gravity, which comprised a greater percentage of the total joint moment during swing as compared to stance. Peak hip and knee flexor and extensor moments during swing were significantly greater when calculated using cadaver data (p<0.05). These differences were greater while walking fast as compared to slow speeds. A significant difference was not found between these two methods for peak hip and knee moments during stance. A significant difference was found for peak ankle joint moments during stance, but the magnitude was not clinically important. These results support the use of direct measurements of anthropometry when examining above-knee prosthetic gait, particularly during swing.

Entities:  

Mesh:

Year:  2007        PMID: 18031751     DOI: 10.1016/j.jbiomech.2007.10.002

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  8 in total

Review 1.  Methodological factors affecting joint moments estimation in clinical gait analysis: a systematic review.

Authors:  Valentina Camomilla; Andrea Cereatti; Andrea Giovanni Cutti; Silvia Fantozzi; Rita Stagni; Giuseppe Vannozzi
Journal:  Biomed Eng Online       Date:  2017-08-18       Impact factor: 2.819

2.  Amputee locomotion: determining the inertial properties of running-specific prostheses.

Authors:  Brian S Baum; Melanie P Schultz; Andrea Tian; Benjamin Shefter; Erik J Wolf; Hyun Joon Kwon; Jae Kun Shim
Journal:  Arch Phys Med Rehabil       Date:  2013-03-28       Impact factor: 3.966

3.  Vacuum level effects on gait characteristics for unilateral transtibial amputees with elevated vacuum suspension.

Authors:  Hang Xu; Kasey Greenland; Donald Bloswick; Jie Zhao; Andrew Merryweather
Journal:  Clin Biomech (Bristol, Avon)       Date:  2017-02-14       Impact factor: 2.063

4.  Motor adaptation to prosthetic cycling in people with trans-tibial amputation.

Authors:  W Lee Childers; Boris I Prilutsky; Robert J Gregor
Journal:  J Biomech       Date:  2014-04-26       Impact factor: 2.712

5.  Anthropometric and biomechanical characteristics of body segments in persons with spinal cord injury.

Authors:  Y Fang; L R Morse; N Nguyen; N G Tsantes; K L Troy
Journal:  J Biomech       Date:  2017-02-03       Impact factor: 2.712

6.  Kinematic and biomimetic assessment of a hydraulic ankle/foot in level ground and camber walking.

Authors:  Xuefei Bai; David Ewins; Andrew D Crocombe; Wei Xu
Journal:  PLoS One       Date:  2017-07-13       Impact factor: 3.240

7.  An Investigation into a Gear-Based Knee Joint Designed for Lower Limb Prosthesis.

Authors:  M S H Bhuiyan; I A Choudhury; M Dahari; Y Nukman; S Z Dawal
Journal:  Appl Bionics Biomech       Date:  2017-05-05       Impact factor: 1.781

8.  A biomechanical assessment of hydraulic ankle-foot devices with and without micro-processor control during slope ambulation in trans-femoral amputees.

Authors:  Xuefei Bai; David Ewins; Andrew David Crocombe; Wei Xu
Journal:  PLoS One       Date:  2018-10-05       Impact factor: 3.240

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.