Literature DB >> 18029208

The effect of the rotational angle on MR diffusion indices in nerves: is the rms displacement of the slow-diffusing component a good measure of fiber orientation?

Amnon Bar-Shir1, Yoram Cohen.   

Abstract

In recent years, much effort has been made to increase our ability to infer nerve fiber direction through the use of diffusion MR. The present study examines the effect of the rotational angle (alpha), i.e. the angle between the diffusion sensitizing gradients and the main axis of the fibers in the nerves, on different NMR indices. The indices examined were the apparent diffusion coefficient (ADC), extracted from low b-values (b(max) approximately 1200 s/mm(2)), and the root mean square (rms) displacement of the fast and the slow-diffusing components extracted from high b-value q-space diffusion MR data. In addition, the effect of both the diffusion time and myelination was evaluated. We found that the most sensitive index to the rotational angle is the rms displacement of the slow-diffusing component extracted from the high b-value q-space diffusion MR experiment. For this component the rms displacement was nearly constant for alpha values ranging from -10 degrees to +80 degrees (where alpha=0 degrees is the z direction), but it changed dramatically when diffusion was measured nearly perpendicular to the nerve fiber direction, i.e., for alpha=90+/-10 degrees. The ADC and the rms displacement of the fast-diffusing component exhibited only gradual changes, with a maximal change at alpha=45+/-15 degrees. The sensitivity of the rms displacement of the slow-diffusing component to the rotational angle was found to be higher at longer diffusion times and in mature fully myelinated nerves. The relevance of these observations for determining the fiber direction is briefly discussed.

Mesh:

Year:  2007        PMID: 18029208     DOI: 10.1016/j.jmr.2007.10.007

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  3 in total

Review 1.  From single-pulsed field gradient to double-pulsed field gradient MR: gleaning new microstructural information and developing new forms of contrast in MRI.

Authors:  Noam Shemesh; Evren Ozarslan; Michal E Komlosh; Peter J Basser; Yoram Cohen
Journal:  NMR Biomed       Date:  2010-08       Impact factor: 4.044

2.  Detecting diffusion-diffraction patterns in size distribution phantoms using double-pulsed field gradient NMR: Theory and experiments.

Authors:  Noam Shemesh; Evren Ozarslan; Peter J Basser; Yoram Cohen
Journal:  J Chem Phys       Date:  2010-01-21       Impact factor: 3.488

3.  Observation of restricted diffusion in the presence of a free diffusion compartment: single- and double-PFG experiments.

Authors:  Noam Shemesh; Evren Ozarslan; Amnon Bar-Shir; Peter J Basser; Yoram Cohen
Journal:  J Magn Reson       Date:  2009-07-09       Impact factor: 2.229

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.