Literature DB >> 18023219

Optimum pulse flip angles for multi-scan acquisition of hyperpolarized NMR and MRI.

Kaz Nagashima1.   

Abstract

The optimum pulse flip angles were calculated for multi-scan acquisition of hyperpolarized NMR and MRI. The derived formulae could be correlated with the best angle for ordinary steady-state acquisition, the so-called Ernst angle. Although single-scan acquisition has been popular in hyperpolarized measurements, signal accumulation by increasing scans may become very effective for improving the total signal gain, especially when the sample's longitudinal spin relaxation time is long. The optimum angles were calculated from theoretical relations between the exponential of the pulse repetition time/relaxation time ratio and the total scan counts. Constant and variable flip angle cases are presented, both of which yield similar cumulative signal amplitudes. For the constant angle case, a numerically calculated semi-universal curve is presented for the rough estimation of the best angle, as the results were not significantly dependent upon the degree of hyperpolarization within the realistic range. Meanwhile, for the variable angle case, the best angles were approximated from a clean trigonometric series relation, in which the initial pulse became near the Ernst angle and the last pulse was always 90 degrees . A modification of the variable angle scheme enables the acquisition of uniform signal amplitude throughout all scans.

Mesh:

Year:  2007        PMID: 18023219     DOI: 10.1016/j.jmr.2007.10.011

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  20 in total

1.  A method for simultaneous echo planar imaging of hyperpolarized ¹³C pyruvate and ¹³C lactate.

Authors:  Galen D Reed; Peder E Z Larson; Cornelius von Morze; Robert Bok; Michael Lustig; Adam B Kerr; John M Pauly; John Kurhanewicz; Daniel B Vigneron
Journal:  J Magn Reson       Date:  2012-02-24       Impact factor: 2.229

2.  Effects of excitation angle strategy on quantitative analysis of hyperpolarized pyruvate.

Authors:  Christopher M Walker; David Fuentes; Peder E Z Larson; Vikas Kundra; Daniel B Vigneron; James A Bankson
Journal:  Magn Reson Med       Date:  2019-02-22       Impact factor: 4.668

3.  Generating super stimulated-echoes in MRI and their application to hyperpolarized C-13 diffusion metabolic imaging.

Authors:  Peder E Z Larson; Adam B Kerr; Galen D Reed; Ralph E Hurd; John Kurhanewicz; John M Pauly; Daniel B Vigneron
Journal:  IEEE Trans Med Imaging       Date:  2011-10-21       Impact factor: 10.048

4.  A regional bolus tracking and real-time B1 calibration method for hyperpolarized 13 C MRI.

Authors:  Shuyu Tang; Eugene Milshteyn; Galen Reed; Jeremy Gordon; Robert Bok; Xucheng Zhu; Zihan Zhu; Daniel B Vigneron; Peder E Z Larson
Journal:  Magn Reson Med       Date:  2018-09-18       Impact factor: 4.668

5.  Calibration of RF transmitter voltages for hyperpolarized gas MRI.

Authors:  Adil Bashir; Mark S Conradi; Jason C Woods; James D Quirk; Ddmitriy A Yablonskiy
Journal:  Magn Reson Med       Date:  2009-01       Impact factor: 4.668

6.  Multiband excitation pulses for hyperpolarized 13C dynamic chemical-shift imaging.

Authors:  Peder E Z Larson; Adam B Kerr; Albert P Chen; Michael S Lustig; Matthew L Zierhut; Simon Hu; Charles H Cunningham; John M Pauly; John Kurhanewicz; Daniel B Vigneron
Journal:  J Magn Reson       Date:  2008-06-24       Impact factor: 2.229

7.  Rapid in vivo apparent diffusion coefficient mapping of hyperpolarized (13) C metabolites.

Authors:  Bertram L Koelsch; Galen D Reed; John Kurhanewicz; Peder E Z Larson; Kayvan R Keshari; Myriam M Chaumeil; Robert Bok; Sabrina M Ronen; Daniel B Vigneron
Journal:  Magn Reson Med       Date:  2014-09-11       Impact factor: 4.668

8.  A metabolite-specific 3D stack-of-spiral bSSFP sequence for improved lactate imaging in hyperpolarized [1-13 C]pyruvate studies on a 3T clinical scanner.

Authors:  Shuyu Tang; Robert Bok; Hecong Qin; Galen Reed; Mark VanCriekinge; Romelyn Delos Santos; William Overall; Juan Santos; Jeremy Gordon; Zhen Jane Wang; Daniel B Vigneron; Peder E Z Larson
Journal:  Magn Reson Med       Date:  2020-02-21       Impact factor: 4.668

9.  Optimal variable flip angle schemes for dynamic acquisition of exchanging hyperpolarized substrates.

Authors:  Yan Xing; Galen D Reed; John M Pauly; Adam B Kerr; Peder E Z Larson
Journal:  J Magn Reson       Date:  2013-06-14       Impact factor: 2.229

10.  A 300-fold enhancement of imino nucleic acid resonances by hyperpolarized water provides a new window for probing RNA refolding by 1D and 2D NMR.

Authors:  Mihajlo Novakovic; Gregory L Olsen; György Pintér; Daniel Hymon; Boris Fürtig; Harald Schwalbe; Lucio Frydman
Journal:  Proc Natl Acad Sci U S A       Date:  2020-01-16       Impact factor: 11.205

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.