Literature DB >> 1802133

Imaging of diffusion and microcirculation with gradient sensitization: design, strategy, and significance.

D Le Bihan1, R Turner, C T Moonen, J Pekar.   

Abstract

Recent developments in the use of magnetic resonance (MR) to measure and image diffusion and blood microcirculation ("perfusion") are summarized. After a brief description of the effects of diffusion and perfusion on the MR signal, the different methods (conventional spin-echo, stimulated-echo, gradient-echo, and echo-planar imaging) that have been proposed and used to image and measure diffusion and perfusion by gradient sensitization are presented, along with their advantages and limitations. The difficulties of diffusion/perfusion imaging related to both hardware and software are then discussed. Special attention is given to specific problems encountered with in vivo studies and data analysis. Finally, the potential biologic and clinical applications are outlined, and some examples are presented.

Mesh:

Year:  1991        PMID: 1802133     DOI: 10.1002/jmri.1880010103

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  49 in total

1.  Magnetisation transfer ratio and mean diffusivity of normal appearing white and grey matter from patients with multiple sclerosis.

Authors:  M Cercignani; M Bozzali; G Iannucci; G Comi; M Filippi
Journal:  J Neurol Neurosurg Psychiatry       Date:  2001-03       Impact factor: 10.154

2.  Transient decrease in water diffusion observed in human occipital cortex during visual stimulation.

Authors:  A Darquié; J B Poline; C Poupon; H Saint-Jalmes; D Le Bihan
Journal:  Proc Natl Acad Sci U S A       Date:  2001-07-17       Impact factor: 11.205

3.  Mean diffusivity and fractional anisotropy histograms of patients with multiple sclerosis.

Authors:  M Cercignani; M Inglese; E Pagani; G Comi; M Filippi
Journal:  AJNR Am J Neuroradiol       Date:  2001-05       Impact factor: 3.825

4.  Hemodialysis increases apparent diffusion coefficient of brain water in nephrectomized rats measured by isotropic diffusion-weighted magnetic resonance imaging.

Authors:  J P Galons; T Trouard; A F Gmitro; Y H Lien
Journal:  J Clin Invest       Date:  1996-08-01       Impact factor: 14.808

5.  Quantitative diffusion tensor MR imaging of the brain: field strength related variance of apparent diffusion coefficient (ADC) and fractional anisotropy (FA) scalars.

Authors:  Thierry A G M Huisman; Thomas Loenneker; Gerd Barta; Matthias E Bellemann; Juergen Hennig; Joachim E Fischer; Kamil A Il'yasov
Journal:  Eur Radiol       Date:  2006-03-11       Impact factor: 5.315

6.  Intravoxel incoherent motion MR imaging: comparison of diffusion and perfusion characteristics between nasopharyngeal carcinoma and post-chemoradiation fibrosis.

Authors:  Vincent Lai; Xiao Li; Victor Ho Fun Lee; Ka On Lam; Queenie Chan; Pek Lan Khong
Journal:  Eur Radiol       Date:  2013-05-31       Impact factor: 5.315

Review 7.  Spinal cord MRI in multiple sclerosis--diagnostic, prognostic and clinical value.

Authors:  Hugh Kearney; David H Miller; Olga Ciccarelli
Journal:  Nat Rev Neurol       Date:  2015-05-26       Impact factor: 42.937

Review 8.  Functional MRI and CT biomarkers in oncology.

Authors:  J M Winfield; G S Payne; N M deSouza
Journal:  Eur J Nucl Med Mol Imaging       Date:  2015-01-13       Impact factor: 9.236

9.  In vivo magnetic resonance imaging and spectroscopy. Technological advances and opportunities for applications continue to abound.

Authors:  Peter van Zijl; Linda Knutsson
Journal:  J Magn Reson       Date:  2019-07-09       Impact factor: 2.229

10.  Relevance of the skewness index in DTI exploration of multiple sclerosis.

Authors:  Eliane Graulières; Jean-Albert Lotterie; Emmanuelle Cassol; Angélique Gerdelat; Michel Clanet; Isabelle Berry
Journal:  MAGMA       Date:  2008-11-08       Impact factor: 2.310

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.