Literature DB >> 17998123

Initial intervertebral stability after anterior cervical discectomy and fusion with plating.

David Mourning1, Charles A Reitman, Michael H Heggeness, Stephen I Esses, John A Hipp.   

Abstract

BACKGROUND CONTEXT: Anterior cervical locking plates are currently used to provide secure fixation, which appears to help promote fusion, although the details of the in vivo biomechanical effects of plating on the spine are unknown.
PURPOSE: To determine if any motion was present initially in the plated anterior cervical discectomy and fusion (ACDF) and, if so, where the motion occurred. STUDY
DESIGN: A cohort of patients that were part of a prospective study on postoperative changes after cervical fusion were evaluated for motion at the fusion site about 2 weeks after ACDF.
METHODS: Forty-eight segments in 27 patients undergoing ACDF with a cervical plate were evaluated. The patients underwent flexion and extension radiography approximately 2 weeks after surgery. Intervertebral motion at the fusion site was evaluated with validated quantitative motion analysis.
RESULTS: Motion was perceived at 29 levels in 18 patients. The sources of motion were either actual bending of the plate itself, motion at the screw-bone interface, or screw-plate interface.
CONCLUSIONS: In many patients, anterior cervical plating after ACDF does not eliminate motion at the fusion site. Depending on the quality of bone, type of bone graft, and nature of the injury, this information may influence decisions regarding implants and postoperative bracing.

Entities:  

Mesh:

Year:  2007        PMID: 17998123     DOI: 10.1016/j.spinee.2006.10.024

Source DB:  PubMed          Journal:  Spine J        ISSN: 1529-9430            Impact factor:   4.166


  7 in total

1.  Early Radiographic and Clinical Outcomes Study Evaluating an Integrated Screw and Interbody Spacer for One- and Two-Level ACDF.

Authors:  Paul D Lane; Jacob L Cox; Roger B Gaskins; Brandon G Santoni; James B Billys; Antonio E Castellvi
Journal:  Int J Spine Surg       Date:  2015-07-17

2.  Can an Endplate-conformed Cervical Cage Provide a Better Biomechanical Environment than a Typical Non-conformed Cage?: A Finite Element Model and Cadaver Study.

Authors:  Fan Zhang; Hao-Cheng Xu; Bo Yin; Xin-Lei Xia; Xiao-Sheng Ma; Hong-Li Wang; Jun Yin; Ming-Hao Shao; Fei-Zhou Lyu; Jian-Yuan Jiang
Journal:  Orthop Surg       Date:  2016-08       Impact factor: 2.071

3.  Biomechanical testing of circumferential instrumentation after cervical multilevel corpectomy.

Authors:  Sebastian Hartmann; Claudius Thomé; Alexander Keiler; Helga Fritsch; Aldemar Andres Hegewald; Werner Schmölz
Journal:  Eur Spine J       Date:  2015-08-02       Impact factor: 3.134

4.  Biomechanical evaluation of a low profile, anchored cervical interbody spacer device in the setting of progressive flexion-distraction injury of the cervical spine.

Authors:  Bartosz Wojewnik; Alexander J Ghanayem; Parmenion P Tsitsopoulos; Leonard I Voronov; Tejaswy Potluri; Robert M Havey; Julia Zelenakova; Alpesh A Patel; Gerard Carandang; Avinash G Patwardhan
Journal:  Eur Spine J       Date:  2012-08-01       Impact factor: 3.134

5.  The Utility of Cervical Spine Bracing As a Postoperative Adjunct to Multilevel Anterior Cervical Spine Surgery.

Authors:  Ian F Caplan; Saurabh Sinha; Benjamin Osiemo; Scott D McClintock; James M Schuster; Harvey Smith; Gregory Glauser; Nikhil Sharma; Ali K Ozturk; Zarina S Ali; Neil R Malhotra
Journal:  Int J Spine Surg       Date:  2020-04-30

6.  The Utility of Cervical Spine Bracing as a Postoperative Adjunct to Single-level Anterior Cervical Spine Surgery.

Authors:  Ian Caplan; Saurabh Sinha; James Schuster; Matthew Piazza; Gregory Glauser; Benjamin Osiemo; Scott McClintock; William C Welch; Nikhil Sharma; Ali Ozturk; Neil Rainer Malhotra
Journal:  Asian J Neurosurg       Date:  2019 Apr-Jun

7.  Risk Factors and Radiologic Changes in Subsidence after Single-Level Anterior Cervical Corpectomy: A Minimum Follow-Up of 2 Years.

Authors:  Tae Yong An; Ji-Yoon Kim; Young-Seok Lee
Journal:  Korean J Neurotrauma       Date:  2021-09-03
  7 in total