Analytical performances of the D-dimer assay for the Immulite 2000 automated immunoassay analyser.

G Lippi1, G L Salvagno, L Rossi, M Montagnana, M Franchini, G C Guidi.   

Abstract

We evaluated the analytical performances of a new commercial chemiluminescent enzyme immunometric assay for d-dimer measurement on the Immulite 2000 automated analyser. The within- and between-run coefficients of variations for low, intermediate and high d-dimer concentrations ranged from 2.2% to 5.1% and from 2.9% to 6.0% respectively. The assay was proven linear in a range of d-dimer concentrations comprised between 324 and 7602 ng/ml. Comparison of samples collected in either 0.109 mol/l sodium citrate or lithium-heparin tubes by Bland-Altman plots and nonparametric regression analysis (y = 0.858x - 39, r = 0.997; P < 0.0001) revealed a minimum bias, almost completely attributable to the dilution effect of the anticoagulant. Results of 56 outpatients' citrated plasma samples analysed with the Immulite 2000 d-dimer assay were compared with those of the current reference commercial immunoassay on the Mini Vidas Immunoanalyser. Although the nonparametric regression according to the method of Passing and Bablok and the relative Spearman's correlation coefficient was satisfactory (Immulite = 1.001 x Vidas - 181; r = 0.937, P < 0.001), some random discrepancies could be observed in Bland-Altman plots analysis. The analytical accuracy, calculated as the area under the Receiver Operating Characteristic (ROC) curve (AUC), was 0.961 (P < 0.0001). On the basis of the results of the present evaluation, we conclude that the analytical performances and the main technical features of new Immulite 2000 d-dimer assay make it a suitable method for the rapid quantification of d-dimer in clinical laboratories.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17988295     DOI: 10.1111/j.1751-553X.2007.00938.x

Source DB:  PubMed          Journal:  Int J Lab Hematol        ISSN: 1751-5521            Impact factor:   2.877


  3 in total

1.  Fluorescence immunoassay of human D-dimer in whole blood.

Authors:  Tae Kyum Kim; Sang Wook Oh; Young Joon Mok; Eui Yul Choi
Journal:  J Clin Lab Anal       Date:  2014-02-27       Impact factor: 2.352

Review 2.  Biochemical markers for the diagnosis of venous thromboembolism: the past, present and future.

Authors:  Giuseppe Lippi; Gianfranco Cervellin; Massimo Franchini; Emmanuel J Favaloro
Journal:  J Thromb Thrombolysis       Date:  2010-11       Impact factor: 2.300

3.  Analytical performance of a new immunoturbidimetric D-dimer assay and comparison with available assays.

Authors:  Laurie Talon; Virginie Fourneyron; Alexandre Trapani; Bruno Pereira; Thomas Sinegre; Aurélien Lebreton
Journal:  Res Pract Thromb Haemost       Date:  2022-02-06
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.