Literature DB >> 24578175

Fluorescence immunoassay of human D-dimer in whole blood.

Tae Kyum Kim1, Sang Wook Oh, Young Joon Mok, Eui Yul Choi.   

Abstract

BACKGROUND: D-dimer is a widely used biomarker for the initial clinical assessment of suspected deep vein thrombosis and pulmonary embolism. Here, we presented a new fluorescence (FL) D-dimer assay system, which was developed with a platform of point-of-care test (POCT) for clinical applications.
METHODS: Whole blood was mixed with FL-labeled anti-D-dimer detector antibody, and then loaded onto a disposable cartridge. After 12 min of incubation, the FL intensity was acquired by scanning of test cartridge and converted as level of D-dimer in a laser FL scanner. The analytical performance of FL immunoassay was evaluated by linearity, recovery, and precision tests. The comparability of the developed assay was examined with automated reference methods.
RESULTS: The FL assay system showed a good linearity, and the analytical mean recovery of control was 103% in a dynamic working range. The imprecision of intra- and inter-as-say of coefficient of variations from assay system was less than 8%. The developed FL assay system showed strong correlation with two automated reference assays, Vidas D-dimer (r = 0.973) and Stalia D-dimer (r = 0.971).
CONCLUSION: The new FL immunoassay for D-dimer is a user-friendly, precise, and reproducible platform of POCT in whole blood.
© 2014 Wiley Periodicals, Inc.

Entities:  

Keywords:  D-dimer; fluorescence; immunochromatographic assay; point-of-care test (POCT); whole blood

Mesh:

Substances:

Year:  2014        PMID: 24578175      PMCID: PMC6807400          DOI: 10.1002/jcla.21683

Source DB:  PubMed          Journal:  J Clin Lab Anal        ISSN: 0887-8013            Impact factor:   2.352


  26 in total

1.  Performance characteristics of the AxSYM D-dimer assay.

Authors:  Sonia L La'ulu; Camille M Dominguez; William L Roberts
Journal:  Clin Chim Acta       Date:  2008-01-26       Impact factor: 3.786

Review 2.  VIDAS D-dimer in combination with clinical pre-test probability to rule out pulmonary embolism. A systematic review of management outcome studies.

Authors:  Marc Carrier; Marc Righini; Reza Karami Djurabi; Menno V Huisman; Arnaud Perrier; Philip S Wells; Marc Rodger; Walter A Wuillemin; Grégoire Le Gal
Journal:  Thromb Haemost       Date:  2009-05       Impact factor: 5.249

3.  Limitations of D-dimer testing in unselected inpatients with suspected venous thromboembolism.

Authors:  Daniel J Brotman; Jodi B Segal; Jayesh T Jani; Brent G Petty; Thomas S Kickler
Journal:  Am J Med       Date:  2003-03       Impact factor: 4.965

4.  Presenting D-dimer and early symptom severity are independent predictors for post-thrombotic syndrome following a first deep vein thrombosis.

Authors:  Lara N Roberts; Raj K Patel; Paradzai B Chitongo; Lynda Bonner; Roopen Arya
Journal:  Br J Haematol       Date:  2013-01-07       Impact factor: 6.998

Review 5.  Pulmonary embolism in pregnancy. Consensus and controversies.

Authors:  M D Benson
Journal:  Minerva Ginecol       Date:  2012-10

Review 6.  Review of the evidence on diagnosis of deep venous thrombosis and pulmonary embolism.

Authors:  Jodi B Segal; John Eng; Leonardo J Tamariz; Eric B Bass
Journal:  Ann Fam Med       Date:  2007 Jan-Feb       Impact factor: 5.166

Review 7.  D-dimer testing in pregnancy.

Authors:  Sabine Eichinger
Journal:  Pathophysiol Haemost Thromb       Date:  2003 Sep-2004 Dec

8.  Comparison of an immuno-turbidometric method (STalia D-DI) with an established enzyme linked fluorescent assay (VIDAS) D-dimer for the exclusion of venous thromboembolism.

Authors:  K Sukhu; J Beavis; P M Baker; D M Keeling
Journal:  Int J Lab Hematol       Date:  2008-06       Impact factor: 2.877

9.  Diagnostic accuracy of the Triage D-dimer test for exclusion of venous thromboembolism in outpatients.

Authors:  Timothy Ghys; Wim Achtergael; Inge Verschraegen; Barbara Leus; Kristin Jochmans
Journal:  Thromb Res       Date:  2007-09-20       Impact factor: 3.944

10.  Performance of two relatively new quantitative D-dimer assays (Innovance D-dimer and AxSYM D-dimer) for the exclusion of deep vein thrombosis.

Authors:  J L Elf; K Strandberg; P J Svensson
Journal:  Thromb Res       Date:  2009-08-14       Impact factor: 3.944

View more
  1 in total

1.  What's New in Critical Illness and Injury Science? D-Dimer point of care testing for thromboembolic emergencies presenting to the emergency department.

Authors:  Sarathi Kalra; Galwankar Sagar
Journal:  Int J Crit Illn Inj Sci       Date:  2014-07
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.