Changes in pupil size and centroid shift in eyes with uncomplicated in-the-bag IOL implantation.

Gungor Sobaci1, Uzeyir Erdem, Yusuf Uysal, Orkun Muftuoglu.   

Abstract

PURPOSE: To determine changes in entrance pupil size and pupil center shift under low mesopic and photopic conditions of illumination in eyes with in-the-bag intraocular lens (IOL) implantation.
METHODS: Entrance pupil size and pupil center shift were measured under low mesopic (0.06 lux) and photopic (60 lux) conditions of illumination in 55 patients with unilateral pseudophakia (study group) and 55 age- and sex-matched patients with bilateral cataracts (control group) using the NIDEK OPD-Scan. Pseudophakic eyes had an uncomplicated intraoperative and postoperative course and best spectacle-corrected visual acuity of 20/20. Cataractous eyes had no additional ocular or systemic problems affecting the pupil. Both groups were analyzed with respect to pupil size and shift in both conditions of illumination.
RESULTS: Mean patient age was 64.2 +/- 6.8 and 63.6 +/- 4.3 years in the study and control groups, respectively (P = .45). In the study group, differences in pupil size under low mesopic (5.12 +/- 1.02 and 5.13 +/- 0.96 mm for pseudophakic and phakic eyes, respectively) and photopic (3.44 +/- 0.39 and 3.45 +/- 0.39 mm for pseudophakic and phakic eyes, respectively) conditions of illumination were not statistically significant (P = 1.00 and P = .95 for pseudophakic and phakic eyes, respectively). Differences in pupil shift between pseudophakic (0.11 +/- 0.08 mm) and phakic (0.12 +/- 0.10 mm) eyes were not statistically significant (P = .83) in the study group. In the control group, differences in pupil size under low mesopic (P = .59) and photopic conditions of illumination (P = .60) in the right and left eyes as well as pupil shift (P = .71) were not statistically significant.
CONCLUSIONS: Uncomplicated in-the-bag IOL implantation has no influence on pupil size and shift.

Entities:  

Mesh:

Year:  2007        PMID: 17985799     DOI: 10.3928/1081-597X-20071001-09

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  3 in total

1.  [Pupil centroid shift: Marketing tool or essential clinical parameter?].

Authors:  I Fischinger; T G Seiler; G Schmidinger; T Seiler
Journal:  Ophthalmologe       Date:  2015-08       Impact factor: 1.059

2.  Clear-cornea cataract surgery: pupil size and shape changes, along with anterior chamber volume and depth changes. A Scheimpflug imaging study.

Authors:  Anastasios John Kanellopoulos; George Asimellis
Journal:  Clin Ophthalmol       Date:  2014-10-24

3.  Pupil dynamics after in-the-bag versus anterior and retropupillary iris-fixated intraocular lens implantation.

Authors:  Yanxiu Sun; Maximilian Hammer; Timur M Yildirim; Ramin Khoramnia; Gerd U Auffarth
Journal:  Sci Rep       Date:  2021-11-02       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.