Importance of point-by-point back projection correction for isocentric motion in digital breast tomosynthesis: relevance to morphology of structures such as microcalcifications.

Ying Chen1, Joseph Y Lo, James T Dobbins.   

Abstract

Digital breast tomosynthesis is a three-dimensional imaging technique that provides an arbitrary set of reconstruction planes in the breast from a limited-angle series of projection images acquired while the x-ray tube moves. Traditional shift-and-add (SAA) tomosynthesis reconstruction is a common mathematical method to line up each projection image based on its shifting amount to generate reconstruction slices. With parallel-path geometry of tube motion, the path of the tube lies in a plane parallel to the plane of the detector. The traditional SAA algorithm gives shift amounts for each projection image calculated only along the direction of x-ray tube movement. However, with the partial isocentric motion of the x-ray tube in breast tomosynthesis, small objects such as microcalcifications appear blurred (for instance, about 1-4 pixels in blur for a microcalcification in a human breast) in traditional SAA images in the direction perpendicular to the direction of tube motion. Some digital breast tomosynthesis algorithms reported in the literature utilize a traditional one-dimensional SAA method that is not wholly suitable for isocentric motion. In this paper, a point-by-point back projection (BP) method is described and compared with traditional SAA for the important clinical task of evaluating morphology of small objects such as microcalcifications. Impulse responses at different three-dimensional locations with five different combinations of imaging acquisition parameters were investigated. Reconstruction images of microcalcifications in a human subject were also evaluated. Results showed that with traditional SAA and 45 degrees view angle of tube movement with respect to the detector, at the same height above the detector, the in-plane blur artifacts were obvious for objects farther away from x-ray source. In a human subject, the appearance of calcifications was blurred in the direction orthogonal to the tube motion with traditional SAA. With point-by-point BP, the appearance of calcifications was sharper. The point-by-point BP method demonstrated improved rendition of microcalcifications in the direction perpendicular to the tube motion direction. With wide angles or for imaging of larger breasts, this point-by-point BP rather than the traditional SAA should also be considered as the basis of further deblurring algorithms that work in conjunction with the BP method.

Entities:  

Mesh:

Year:  2007        PMID: 17985634     DOI: 10.1118/1.2776256

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  18 in total

1.  Computer-aided detection of clustered microcalcifications in digital breast tomosynthesis: a 3D approach.

Authors:  Berkman Sahiner; Heang-Ping Chan; Lubomir M Hadjiiski; Mark A Helvie; Jun Wei; Chuan Zhou; Yao Lu
Journal:  Med Phys       Date:  2012-01       Impact factor: 4.071

2.  A fast, angle-dependent, analytical model of CsI detector response for optimization of 3D x-ray breast imaging systems.

Authors:  Melanie Freed; Subok Park; Aldo Badano
Journal:  Med Phys       Date:  2010-06       Impact factor: 4.071

3.  Digital Breast Tomosynthesis: State of the Art.

Authors:  Srinivasan Vedantham; Andrew Karellas; Gopal R Vijayaraghavan; Daniel B Kopans
Journal:  Radiology       Date:  2015-12       Impact factor: 11.105

Review 4.  Anniversary paper. Development of x-ray computed tomography: the role of medical physics and AAPM from the 1970s to present.

Authors:  Xiaochuan Pan; Jeffrey Siewerdsen; Patrick J La Riviere; Willi A Kalender
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

5.  Automated breast mass detection in 3D reconstructed tomosynthesis volumes: a featureless approach.

Authors:  Swatee Singh; Georgia D Tourassi; Jay A Baker; Ehsan Samei; Joseph Y Lo
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

Review 6.  Tomosynthesis imaging: at a translational crossroads.

Authors:  James T Dobbins
Journal:  Med Phys       Date:  2009-06       Impact factor: 4.071

7.  Multi-beam X-ray source breast tomosynthesis reconstruction with different algorithms.

Authors:  Weihua Zhou; Xin Qian; Jianping Lu; Otto Zhou; Ying Chen
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2010

8.  Analysis of parenchymal texture with digital breast tomosynthesis: comparison with digital mammography and implications for cancer risk assessment.

Authors:  Despina Kontos; Lynda C Ikejimba; Predrag R Bakic; Andrea B Troxel; Emily F Conant; Andrew D A Maidment
Journal:  Radiology       Date:  2011-07-19       Impact factor: 11.105

9.  Optimized image acquisition for breast tomosynthesis in projection and reconstruction space.

Authors:  Amarpreet S Chawla; Joseph Y Lo; Jay A Baker; Ehsan Samei
Journal:  Med Phys       Date:  2009-11       Impact factor: 4.071

Review 10.  Breast cancer imaging: a perspective for the next decade.

Authors:  Andrew Karellas; Srinivasan Vedantham
Journal:  Med Phys       Date:  2008-11       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.