Resolution and noise trade-off analysis for volumetric CT.

Baojun Li1, Gopal B Avinash, Jiang Hsieh.   

Abstract

Until recently, most studies addressing the trade-off between spatial resolution and quantum noise were performed in the context of single-slice CT. In this study, we extend the theoretical framework of previous works to volumetric CT and further extend it by taking into account the actual shapes of the preferred reconstruction kernels. In the experimental study, we also attempt to explore a three-dimensional approach for spatial resolution measurement, as opposed to the conventional two-dimensional approaches that were widely adopted in previously published studies. By scanning a finite-sized sphere phantom, the MTF was measured from the edge profile along the spherical surface. Cases of different resolutions (and noise levels) were generated by adjusting the reconstruction kernel. To reduce bias, the total photon fluxes were matched: 120 kVp, 200 mA, and 1 s per gantry rotation. All data sets were reconstructed using a modified FDK algorithm under the same condition: Scan field-of-view (SFOV) = 10 cm, and slice thickness = 0.625 mm. The theoretical analysis indicated that the variance of noise is proportional to > 4th power of the spatial resolution. Our experimental results supported this conclusion by showing the relationship is 4.6th (helical) or 5th (axial) power.

Entities:  

Mesh:

Year:  2007        PMID: 17985618     DOI: 10.1118/1.2779128

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  Effect of Reducing Field of View on Multidetector Quantitative Computed Tomography Parameters of Airway Wall Thickness in Asthma.

Authors:  Ajay Sheshadri; Alfonso Rodriguez; Ryan Chen; James Kozlowski; Dana Burgdorf; Tammy Koch; Jaime Tarsi; Rebecca Schutz; Brad Wilson; Kenneth Schechtman; Joseph K Leader; Eric A Hoffman; Mario Castro; Sean B Fain; David S Gierada
Journal:  J Comput Assist Tomogr       Date:  2015 Jul-Aug       Impact factor: 1.826

Review 2.  [Radiation dose in computed tomography. Risks and challenges].

Authors:  M Prokop
Journal:  Radiologe       Date:  2008-03       Impact factor: 0.635

3.  Optimal slice thickness for cone-beam CT with on-board imager.

Authors:  Kyt Seet; A Barghi; S Yartsev; J Van Dyk
Journal:  Biomed Imaging Interv J       Date:  2010-07-01

4.  Optimal slice thickness for object detection with longitudinal partial volume effects in computed tomography.

Authors:  Pascal Monnin; Nicolas Sfameni; Achille Gianoli; Sandrine Ding
Journal:  J Appl Clin Med Phys       Date:  2016-11-23       Impact factor: 2.102