Literature DB >> 17981922

Reactivity of urinary albumin (microalbumin) assays with fragmented or modified albumin.

Denis Sviridov1, Steven K Drake, Glen L Hortin.   

Abstract

BACKGROUND: Controversy exists regarding occurrence and measurement of structural variants of albumin in urine. In this study, we examined cross-reactivity of in vitro modified albumins in assays for urine albumin (microalbumin).
METHODS: We analyzed albumin modified by reagents, trypsin, or physical treatments or differing in primary sequence (animal albumins) with an immunoturbidimetric assay (Beckman LX20) using goat antiserum and a competitive immunoassay (Siemens Immulite) using a monoclonal antibody. We assessed occurrence of albumin fragments in urine by use of Western blotting of 24 specimens.
RESULTS: Chemical modification, modest sequence substitution (gorilla albumin), or cleavage of albumin by cyanogen bromide (CNBr) had little effect on reactivity in the LX20 assay. Albumin extensively cleaved with trypsin retained partial reactivity. The Immulite assay generally was affected more severely by albumin modifications and sequence changes. Western blots of fresh urine specimens or specimens stored at -80 degrees C showed little albumin fragmentation, but some specimens stored for 3 years at -20 degrees C had extensively fragmented albumin that was detected by the LX20 but not the Immulite assay.
CONCLUSIONS: Nearly equivalent reactivity of intact albumin and CNBr fragments in the immunoturbidimetric assay indicates reactivity of antibodies with multiple epitopes throughout albumin. Therefore, it is difficult to abolish reactivity of albumin in this type of urine albumin assay. Differential sensitivity of 2 assays to albumin modification identifies a potential source of assay nonequivalence in measuring urinary albumin, particularly for specimens stored at -20 degrees C.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17981922     DOI: 10.1373/clinchem.2007.092825

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  11 in total

1.  LC-MS/MS in the Clinical Laboratory - Where to From Here?

Authors:  Stefan Kg Grebe; Ravinder J Singh
Journal:  Clin Biochem Rev       Date:  2011-02

2.  Chapter 1: Definition and classification of CKD.

Authors: 
Journal:  Kidney Int Suppl (2011)       Date:  2013-01

3.  Laboratory measurement of urine albumin and urine total protein in screening for proteinuria in chronic kidney disease.

Authors:  Helen Martin
Journal:  Clin Biochem Rev       Date:  2011-05

4.  Urinary Albumin Detection: Comparison of Two Different Methods.

Authors:  Rossana Molinario; Krizia Pocino; Pio Dante Daloiso; Angela Giannace; Giulia Spirito; Cecilia Zuppi; Mirca Antenucci
Journal:  J Clin Lab Anal       Date:  2016-04-07       Impact factor: 2.352

5.  Effect of storage time at -20°C on markers used for assessment of renal damage in children: albumin, γ-glutamyl transpeptidase, N-acetyl-β-D-glucosaminidase and α1-microglobulin.

Authors:  Felicia Trachtenberg; Lars Barregard
Journal:  Scand J Urol Nephrol       Date:  2010-06-21

Review 6.  Albuminuria: what can we expect from the determination of nonimmunoreactive albumin?

Authors:  Stephan J L Bakker; Ron T Gansevoort; Dick de Zeeuw
Journal:  Curr Hypertens Rep       Date:  2009-04       Impact factor: 5.369

7.  Quantification of urinary albumin by using protein cleavage and LC-MS/MS.

Authors:  Jesse C Seegmiller; David R Barnidge; Bradley E Burns; Timothy S Larson; John C Lieske; Rajiv Kumar
Journal:  Clin Chem       Date:  2009-03-26       Impact factor: 8.327

8.  Proteinuria without albuminuria: urinary protein excretion by a subset of patients with burn injuries.

Authors:  Denis Sviridov; William E Owen; William L Roberts; L S Edelman; Steven K Drake; Glen L Hortin
Journal:  Clin Chim Acta       Date:  2009-01-23       Impact factor: 3.786

Review 9.  Urine Proteomics in the Era of Mass Spectrometry.

Authors:  Ashley Beasley-Green
Journal:  Int Neurourol J       Date:  2016-11-22       Impact factor: 2.835

10.  Moving Toward Standardization of Urine Albumin Measurements.

Authors:  Jesse C Seegmiller; W Greg Miller; Lorin M Bachmann
Journal:  EJIFCC       Date:  2017-12-19