Literature DB >> 17981350

Differences in the definition of internal target volumes using slow CT alone or in combination with thin-slice CT under breath-holding conditions during the planning of stereotactic radiotherapy for lung cancer.

Satoshi Seki1, Etsuo Kunieda, Atsuya Takeda, Tomoaki Nagaoka, Hossain M Deloar, Takatsugu Kawase, Junichi Fukada, Osamu Kawaguchi, Minoru Uematsu, Atsushi Kubo.   

Abstract

PURPOSE: To investigate how the delineations of the internal target volume (ITV) made from 'slow' CT alter with reference to 'thin-slice' CT.
MATERIALS AND METHODS: Thin-slice CT images taken under breath-holding conditions and slow CT images taken under shallow-breathing conditions (8s/image) of 11 lung cancers were used for this study. Five radiation oncologists delineated ITV of the 11 lesions using slow CT images (ITV1), and then redefined them with reference to thin-slice CT images (ITV2). SD-images (standard deviation image) were created for all patients from ITV images in order to visualize the regional variation of the ITVs.
RESULTS: The mean value of ITV2 was smaller than that initially defined by ITV1. There was no significant change in ITV1 and ITV2 between operators with regard to standard deviation in volume. There was a significant difference in the distribution of the ratio of ITV1 to ITV2 obtained on thin-slice CTs between cases with and without ground glass opacity. In cases without ground glass opacity there was a tendency for ITV2 to have a smaller volume than ITV1.
CONCLUSIONS: Combined use of slow CT and thin-slice CT in delineation of ITV contours appeared to be useful in making adjustments for obscured tumor images caused by respiratory movement.

Entities:  

Mesh:

Year:  2007        PMID: 17981350     DOI: 10.1016/j.radonc.2007.10.010

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  3 in total

1.  The potential for undertaking slow CT using a modern CT scanner.

Authors:  C D Chinneck; M McJury; A R Hounsell
Journal:  Br J Radiol       Date:  2010-06-15       Impact factor: 3.039

2.  Recommendations for implementing stereotactic radiotherapy in peripheral stage IA non-small cell lung cancer: report from the Quality Assurance Working Party of the randomised phase III ROSEL study.

Authors:  Coen W Hurkmans; Johan P Cuijpers; Frank J Lagerwaard; Joachim Widder; Uulke A van der Heide; Danny Schuring; Suresh Senan
Journal:  Radiat Oncol       Date:  2009-01-12       Impact factor: 3.481

3.  Reconstitution of internal target volumes by combining four-dimensional computed tomography and a modified slow computed tomography scan in stereotactic body radiotherapy planning for lung cancer.

Authors:  Seong Soon Jang; Gil Ja Huh; Suk Young Park; Po Song Yang; Hae Nam Chung; Jae Hyuk Seo; Ji Chan Park; Young Jun Yang; Eun Youn Cho
Journal:  Radiat Oncol       Date:  2014-05-02       Impact factor: 3.481

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.