Literature DB >> 17980831

Dosimetric characteristics of the Siemens IGRT carbon fiber tabletop.

Emiliano Spezi1, Andrea Ferri.   

Abstract

In this work, the dosimetric characteristics of a new commercial carbon fiber treatment table are investigated. The photon beam attenuation properties of the Siemens image-guided radiation therapy (IGRT) tabletop were studied in detail. Two sets of dosimetric measurements were performed. In the first experiment a polystyrene slab phantom was used: the central axis attenuation and the skin-sparing detriment were investigated. In the second experiment, the off-axis treatment table transmission was investigated using a polystyrene cylindrical phantom. Measurements were taken at the isocenter for a 360 degrees rotation of the radiation beam. Our results show that the photon beam attenuation of the Siemens IGRT carbon fiber tabletop varies from a minimum of 2.1% (central axis) to a maximum of 4.6% (120 degrees and 240 degrees beam incidence). The beam entrance dose increases from 82% to 97% of the dose at the depth of maximum for a clinical 6-MV radiation field. The depth of maximum also decreases by 0.4 cm. Despite the wedge cross section of the table the beam attenuation properties of the IGRT tabletop remain constant along the longitudinal direction. American Association of Medical Dosimetrists.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17980831     DOI: 10.1016/j.meddos.2006.11.006

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  13 in total

1.  Effect of a carbon fiber tabletop on the surface dose and attenuation for high-energy photon beams.

Authors:  Tülay P Meydanci; Gönül Kemikler
Journal:  Radiat Med       Date:  2008-11-22

2.  Effects of Siemens TT-D carbon fiber table top on beam attenuation, and build up region of 6 MV photon beam.

Authors:  Asma Sheykhoo; Sara Abdollahi; Mohammad Hadi Hadizadeh Yazdi; Mahdi Ghorbani; Mohammad Mohammadi
Journal:  Rep Pract Oncol Radiother       Date:  2016-10-17

3.  Verification of the dose attenuation of a newly developed vacuum cushion for intensity-modulated radiation therapy of prostate cancer.

Authors:  Toru Takakura; Yoshiyuki Ito; Akinori Higashikawa; Tomohiro Nishiyama; Takashi Sakamoto
Journal:  Radiol Phys Technol       Date:  2016-06-03

4.  Reduction of Potential Risk for Skin Toxicity in Megavoltage Radiotherapy Using a Novel Rigid Couch.

Authors:  Mikoto Tamura; Hajime Monzen; Kenji Matsumoto; Masahiko Okumura; Hiroshi Doi; Yasumasa Nishimura
Journal:  In Vivo       Date:  2018 May-Jun       Impact factor: 2.155

5.  Absorption ratio of treatment couch and effect on surface and build-up region doses.

Authors:  Taylan Tuğrul
Journal:  Rep Pract Oncol Radiother       Date:  2017-11-20

6.  A validation of carbon fiber imaging couch top modeling in two radiation therapy treatment planning systems: Philips Pinnacle3 and BrainLAB iPlan RT Dose.

Authors:  Christopher F Njeh; Jason Parker; Joseph Spurgin; Elizabeth Rhoe
Journal:  Radiat Oncol       Date:  2012-11-09       Impact factor: 3.481

7.  Characterization of dose impact on IMRT and VMAT from couch attenuation for two Varian couches.

Authors:  Heng Li; Andrew K Lee; Jennifer L Johnson; Ronald X Zhu; Rajat J Kudchadker
Journal:  J Appl Clin Med Phys       Date:  2011-03-02       Impact factor: 2.102

8.  Assessment and management of radiotherapy beam intersections with the treatment couch.

Authors:  Monique Van Prooijen; Thilakshan Kanesalingam; Mohammad K Islam; Robert K Heaton
Journal:  J Appl Clin Med Phys       Date:  2010-04-19       Impact factor: 2.102

9.  An Update of Couch Effect on the Attenuation of Megavoltage Radiotherapy Beam and the Variation of Absorbed Dose in the Build-up Region.

Authors:  T Sedaghatian; M Momennezhad; S H Rasta; Y Makhdoomi; S Abdollahian
Journal:  J Biomed Phys Eng       Date:  2017-09-01

10.  Radiation dosimetry effect evaluation of a carbon fiber couch on novel uRT-linac 506c accelerator.

Authors:  Dazhen Jiang; Zhen Cao; Yongchang Wei; Tingting Cao; Jiuling Shen; Conghua Xie; Yunfeng Zhou; Hui Liu; Jun Zhang
Journal:  Sci Rep       Date:  2021-06-29       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.