An anatomically realistic whole-body pregnant-woman model and specific absorption rates for pregnant-woman exposure to electromagnetic plane waves from 10 MHz to 2 GHz.

Tomoaki Nagaoka1, Toshihiro Togashi2, Kazuyuki Saito3, Masaharu Takahashi3, Koichi Ito4, Soichi Watanabe1.   

Abstract

The numerical dosimetry of pregnant women is an important issue in electromagnetic-field safety. However, an anatomically realistic whole-body pregnant-woman model for electromagnetic dosimetry has not been developed. Therefore, we have developed a high-resolution whole-body model of pregnant women. A new fetus model including inherent tissues of pregnant women was constructed on the basis of abdominal magnetic resonance imaging data of a 26-week-pregnant woman. The whole-body pregnant-woman model was developed by combining the fetus model and a nonpregnant-woman model that was developed previously. The developed model consists of about 7 million cubical voxels of 2 mm size and is segmented into 56 tissues and organs. This pregnant-woman model is the first completely anatomically realistic voxel model that includes a realistic fetus model and enables a numerical simulation of electromagnetic dosimetry up to the gigahertz band. In this paper, we also present the basic specific absorption rate characteristics of the pregnant-woman model exposed to vertically and horizontally polarized electromagnetic waves from 10 MHz to 2 GHz.

Entities:  

Mesh:

Year:  2007        PMID: 17975294     DOI: 10.1088/0031-9155/52/22/012

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  8 in total

1.  Investigation of multichannel phased array performance for fetal MR imaging on 1.5T clinical MR system.

Authors:  Ye Li; Yong Pang; Daniel Vigneron; Orit Glenn; Duan Xu; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2011-01-01

2.  Foetal dose conversion coefficients for ICRP-compliant pregnant models from idealised proton exposures.

Authors:  Valery Taranenko; X George Xu
Journal:  Radiat Prot Dosimetry       Date:  2009-02-26       Impact factor: 0.972

Review 3.  An exponential growth of computational phantom research in radiation protection, imaging, and radiotherapy: a review of the fifty-year history.

Authors:  X George Xu
Journal:  Phys Med Biol       Date:  2014-08-21       Impact factor: 3.609

4.  [Radiology and pregnancy. Principles, general requirements and exposure].

Authors:  G Weisser; V Steil; K W Neff; K A Büsing
Journal:  Radiologe       Date:  2012-01       Impact factor: 0.635

5.  Individual variation in simulated fetal SAR assessed in multiple body models.

Authors:  Esra Abaci Turk; Filiz Yetisir; Elfar Adalsteinsson; Borjan Gagoski; Bastien Guerin; P Ellen Grant; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2019-10-18       Impact factor: 4.668

6.  Hybrid 3D pregnant woman and fetus modeling from medical imaging for dosimetry studies.

Authors:  Lazar Bibin; Jérémie Anquez; Elsa Angelini; Isabelle Bloch
Journal:  Int J Comput Assist Radiol Surg       Date:  2009-07-18       Impact factor: 2.924

7.  MRI-based multiscale model for electromagnetic analysis in the human head with implanted DBS.

Authors:  Maria Ida Iacono; Nikos Makris; Luca Mainardi; Leonardo M Angelone; Giorgio Bonmassar
Journal:  Comput Math Methods Med       Date:  2013-07-15       Impact factor: 2.238

8.  Associations of Maternal Cell-Phone Use During Pregnancy With Pregnancy Duration and Fetal Growth in 4 Birth Cohorts.

Authors:  Ermioni Tsarna; Marije Reedijk; Laura Ellen Birks; Mònica Guxens; Ferran Ballester; Mina Ha; Ana Jiménez-Zabala; Leeka Kheifets; Aitana Lertxundi; Hyung-Ryul Lim; Jorn Olsen; Llúcia González Safont; Madhuri Sudan; Elisabeth Cardis; Martine Vrijheid; Tanja Vrijkotte; Anke Huss; Roel Vermeulen
Journal:  Am J Epidemiol       Date:  2019-07-01       Impact factor: 4.897

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.