Literature DB >> 17975280

Real-time tracking of tumor motions and deformations along the leaf travel direction with the aid of a synchronized dynamic MLC leaf sequencer.

Martin Tacke1, Simeon Nill, Uwe Oelfke.   

Abstract

Advanced radiotherapeutical techniques like intensity-modulated radiation therapy (IMRT) are based on an accurate knowledge of the location of the radiation target. An accurate dose delivery, therefore, requires a method to account for the inter- and intrafractional target motion and the target deformation occurring during the course of treatment. A method to compensate in real time for changes in the position and shape of the target is the use of a dynamic multileaf collimator (MLC) technique which can be devised to automatically arrange the treatment field according to real-time image information. So far, various approaches proposed for leaf sequencers have had to rely on a priori known target motion data and have aimed to optimize the overall treatment time. Since for a real-time dose delivery the target motion is not known a priori, the velocity range of the leading leaves is restricted by a safety margin to c x v(max) while the following leaves can travel with an additional maximum speed to compensate for the respective target movements. Another aspect to be considered is the tongue and groove effect. A uniform radiation field can only be achieved if the leaf movements are synchronized. The method presented in this note is the first to combine a synchronizing sequencer and real-time tracking with a dynamic MLC. The newly developed algorithm is capable of online optimizing the leaf velocities by minimizing the overall treatment time while at the same time it synchronizes the leaf trajectories in order to avoid the tongue and groove effect. The simultaneous synchronization is performed with the help of an online-calculated mid-time leaf trajectory which is common for all leaf pairs and which takes into account the real-time target motion and deformation information.

Entities:  

Mesh:

Year:  2007        PMID: 17975280     DOI: 10.1088/0031-9155/52/22/N01

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  10 in total

1.  Detailed analysis of latencies in image-based dynamic MLC tracking.

Authors:  Per Rugaard Poulsen; Byungchul Cho; Amit Sawant; Dan Ruan; Paul J Keall
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

2.  Experimental investigation of a moving averaging algorithm for motion perpendicular to the leaf travel direction in dynamic MLC target tracking.

Authors:  Jai-Woong Yoon; Amit Sawant; Yelin Suh; Byung-Chul Cho; Tae-Suk Suh; Paul Keall
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

3.  Electromagnetic-guided dynamic multileaf collimator tracking enables motion management for intensity-modulated arc therapy.

Authors:  Paul J Keall; Amit Sawant; Byungchul Cho; Dan Ruan; Junqing Wu; Per Poulsen; Jay Petersen; Laurence J Newell; Herbert Cattell; Stine Korreman
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-07-07       Impact factor: 7.038

4.  Markerless EPID image guided dynamic multi-leaf collimator tracking for lung tumors.

Authors:  J Rottmann; P Keall; R Berbeco
Journal:  Phys Med Biol       Date:  2013-05-28       Impact factor: 3.609

5.  Synchronized moving aperture radiation therapy (SMART): superimposing tumor motion on IMRT MLC leaf sequences under realistic delivery conditions.

Authors:  Jun Xu; Nikos Papanikolaou; Chengyu Shi; Steve B Jiang
Journal:  Phys Med Biol       Date:  2009-07-30       Impact factor: 3.609

6.  Toward the development of intrafraction tumor deformation tracking using a dynamic multi-leaf collimator.

Authors:  Yuanyuan Ge; Ricky T O'Brien; Chun-Chien Shieh; Jeremy T Booth; Paul J Keall
Journal:  Med Phys       Date:  2014-06       Impact factor: 4.071

7.  Advances in 4D radiation therapy for managing respiration: part II - 4D treatment planning.

Authors:  Mihaela Rosu; Geoffrey D Hugo
Journal:  Z Med Phys       Date:  2012-07-15       Impact factor: 4.820

8.  Lung stereotactic body radiotherapy with an MR-linac - Quantifying the impact of the magnetic field and real-time tumor tracking.

Authors:  Martin J Menten; Martin F Fast; Simeon Nill; Cornelis P Kamerling; Fiona McDonald; Uwe Oelfke
Journal:  Radiother Oncol       Date:  2016-05-08       Impact factor: 6.280

Review 9.  Expanding the use of real-time electromagnetic tracking in radiation oncology.

Authors:  Amish P Shah; Patrick A Kupelian; Twyla R Willoughby; Sanford L Meeks
Journal:  J Appl Clin Med Phys       Date:  2011-11-15       Impact factor: 2.102

10.  Determining leaf trajectories for dynamic multileaf collimators with consideration of marker visibility: an algorithm study.

Authors:  Bo Zhao; Jianrong Dai
Journal:  J Radiat Res       Date:  2014-06-08       Impact factor: 2.724

  10 in total