Literature DB >> 17973349

Hydrophilic interaction chromatography for mass spectrometric metabonomic studies of urine.

Simon Cubbon1, Timothy Bradbury, Julie Wilson, Jane Thomas-Oates.   

Abstract

High-performance liquid chromatography (LC) coupled to mass spectrometry (MS) is increasingly being used for urinary metabonomic studies. Most studies utilize reversed-phase separation techniques, which are not suited to retaining highly polar analytes. Metabonomic studies should encompass a representative "fingerprint" that contains the largest amount of information possible. In this work, we have analyzed human urine samples with LC-MS, comparing traditional reversed-phase separation with hydrophilic interaction chromatography (HILIC), using both positive and negative electrospray ionization modes. The resulting data were analyzed using principal components analysis and partial least-squares-discriminant analysis. Discriminant models were developed for the response variables gender, diurnal variation, and age and were evaluated using external test sets to classify their predictive ability. The developed models using both positive and negative ionization mode data for reversed-phase and HILIC separations were very comparable, indicating that HILIC is a suitable method for increasing the fingerprint coverage for LC-MS metabonomic studies.

Entities:  

Mesh:

Year:  2007        PMID: 17973349     DOI: 10.1021/ac071008v

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  13 in total

1.  Global metabolic profiling procedures for urine using UPLC-MS.

Authors:  Elizabeth J Want; Ian D Wilson; Helen Gika; Georgios Theodoridis; Robert S Plumb; John Shockcor; Elaine Holmes; Jeremy K Nicholson
Journal:  Nat Protoc       Date:  2010-06       Impact factor: 13.491

Review 2.  Considerations on HILIC and polar organic solvent-based separations: use of cyclodextrin and macrocyclic glycopetide stationary phases.

Authors:  Chunlei Wang; Chunxia Jiang; Daniel W Armstrong
Journal:  J Sep Sci       Date:  2008-06       Impact factor: 3.645

3.  Analytical strategies for LC-MS-based targeted metabolomics.

Authors:  Wenyun Lu; Bryson D Bennett; Joshua D Rabinowitz
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2008-04-29       Impact factor: 3.205

Review 4.  Mass spectrometry strategies in metabolomics.

Authors:  Zhentian Lei; David V Huhman; Lloyd W Sumner
Journal:  J Biol Chem       Date:  2011-06-01       Impact factor: 5.157

5.  Bladder cancer determination via two urinary metabolites: a biomarker pattern approach.

Authors:  Zhenzhen Huang; Lin Lin; Yao Gao; Yongjing Chen; Xiaomei Yan; Jinchun Xing; Wei Hang
Journal:  Mol Cell Proteomics       Date:  2011-07-28       Impact factor: 5.911

6.  Procedures for large-scale metabolic profiling of serum and plasma using gas chromatography and liquid chromatography coupled to mass spectrometry.

Authors:  Warwick B Dunn; David Broadhurst; Paul Begley; Eva Zelena; Sue Francis-McIntyre; Nadine Anderson; Marie Brown; Joshau D Knowles; Antony Halsall; John N Haselden; Andrew W Nicholls; Ian D Wilson; Douglas B Kell; Royston Goodacre
Journal:  Nat Protoc       Date:  2011-06-30       Impact factor: 13.491

7.  Global metabolic profiling of animal and human tissues via UPLC-MS.

Authors:  Elizabeth J Want; Perrine Masson; Filippos Michopoulos; Ian D Wilson; Georgios Theodoridis; Robert S Plumb; John Shockcor; Neil Loftus; Elaine Holmes; Jeremy K Nicholson
Journal:  Nat Protoc       Date:  2012-12-06       Impact factor: 13.491

Review 8.  Metabolite Measurement: Pitfalls to Avoid and Practices to Follow.

Authors:  Wenyun Lu; Xiaoyang Su; Matthias S Klein; Ian A Lewis; Oliver Fiehn; Joshua D Rabinowitz
Journal:  Annu Rev Biochem       Date:  2017-06-20       Impact factor: 23.643

Review 9.  Hydrophilic interaction liquid chromatography (HILIC)--a powerful separation technique.

Authors:  Bogusław Buszewski; Sylwia Noga
Journal:  Anal Bioanal Chem       Date:  2011-08-31       Impact factor: 4.142

10.  Hydrophilic interaction 10 microm I.D. porous layer open tubular columns for ultratrace glycan analysis by liquid chromatography-mass spectrometry.

Authors:  Quanzhou Luo; Tomas Rejtar; Shiaw-Lin Wu; Barry L Karger
Journal:  J Chromatogr A       Date:  2008-10-05       Impact factor: 4.759

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.