Literature DB >> 17971121

Effect of auxiliary grooves on molar crown preparations lacking resistance form: a laboratory study.

Po-Ching Lu1, Peter Wilson1.   

Abstract

PURPOSE: To investigate the effect of auxiliary grooves on resistance to dislodgment of crowns on compromised molar preparations lacking resistance form.
MATERIALS AND METHODS: Thirty human molar teeth were randomly assigned to three groups of ten, and prepared to a height-to-width ratio of 0.3 with a total convergence of 50 degrees , and 1-mm shoulder margin. Base metal alloy copings were constructed with a 45 degrees loading platform and cemented with zinc phosphate cement under a 50 N load. Initially, resistance testing was conducted using a Universal Testing Machine (Instron) at 1 mm/min for all 30 specimens. Following crown dislodgment, Group 1 copings were recemented and retested, Group 2 had one axial groove added, and Group 3 had two axial grooves added. New copings for Groups 2 and 3 were made, cemented, and again tested for resistance. Standardized radiographs were taken prior to initial cementation and scanned into digital images. The percentage of area occupied by the pulpal chamber above the acrylic mounting (PS), and the closest distance to pulp from the preparation surface (CD) were measured.
RESULTS: Recementation or the addition of one groove did not affect the dislodgment values (p > 0.05), but addition of two grooves caused a highly significant increase in resistance (p < 0.001). Regression analysis showed an inverse relationship between initial resistance values and pulpal space area. Lower resistance values were observed when the pulpal space area was large (p= 0.004).
CONCLUSIONS: Crowns can be recemented without affecting resistance to dislodgment. Two grooves should be incorporated into compromised molar crown preparations to increase resistance form. Teeth with large pulps and therefore less coronal dentine have poorer resistance form, and therefore would benefit from placement of auxiliary grooves.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17971121     DOI: 10.1111/j.1532-849X.2007.00263.x

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  4 in total

Review 1.  Tooth preparation for full-coverage restorations-a literature review.

Authors:  Anke Podhorsky; Peter Rehmann; Bernd Wöstmann
Journal:  Clin Oral Investig       Date:  2015-03-07       Impact factor: 3.573

2.  An auxiliary factor for increasing the retention of short abutments.

Authors:  Fendi AlShaarani; Rami M Alaisami; Loai Aljerf; Issam A Jamous; Kanaan Elias; Anas Jaber
Journal:  Heliyon       Date:  2019-10-21

3.  The effect of resistance grooves on the fracture toughness of zirconia-based crowns from mono and cyclic loading.

Authors:  Tarek Q Qasim; Billal M El-Masoud; Ahmed M Abu Laban
Journal:  Eur J Dent       Date:  2018 Oct-Dec

4.  Axial wall angulation for rotational resistance in a theoretical-maxillary premolar model.

Authors:  John F Bowley; Po Lee; Wen-Fu Thomas Lai
Journal:  Clin Exp Dent Res       Date:  2019-08-30
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.