Literature DB >> 17970409

Rehabilitative ultrasound imaging of the lower trapezius muscle: technical description and reliability.

Cliona O'Sullivan1, Susanna Bentman, Kathleen Bennett, Maria Stokes.   

Abstract

STUDY
DESIGN: Exploratory and reliability study.
BACKGROUND: Shoulder dysfunction is common and often difficult to diagnose and treat. The trapezius muscle is an important stabilizer and primary mover of the scapula. The potential use of rehabilitative ultrasound imaging (RUSI) to evaluate scapular muscle function warrants investigation.
OBJECTIVES: To establish a procedure for imaging the thickness of the lower trapezius muscle and to examine reliability within and among investigators.
METHODS: In 16 asymptomatic subjects (12 female, 4 male), aged 20 to 41 years, 3 investigators used RUSI to measure the thickness of the left lower trapezius muscle with the subject at rest in prone. Investigator 1 took 3 images on each of 2 days, while the other 2 investigators took 2 images each on the second day. All measurements of lower trapezius muscle thickness were made off-line, at a point 3 cm lateral to the lateral edge of the spinous processes. To also obtain within-scan reliability, 1 image taken by investigator 1, once displayed on the scanner's screen, was measured 3 times. Investigator 1 also measured lower trapezius muscle thickness 1 cm medial to this site. Reliability was examined using intraclass correlation coefficients (ICC) and the Bland and Altman plot.
RESULTS: The intrarater within-scan reliability at the lateral site was ICC3.3 = 0.99 (95% CI: 0.98 to 1.0). The intrarater between-scan reliability (within-day) at the lateral site, medial site, and combined sites (mean of medial and lateral) were ICC3.3 = 0.96 (95% CI: 0.90 to 0.98), ICC3.2 = 0.90 (95% CI: 0.78 to 0.96), and ICC3.2 = 0.99 (95% CI: 0.99 to 1.0), respectively. Intrarater (between-day) reliability was good for the lateral site and combined sites (ICC3.3 = 0.91, 95% CI: 0.74 to 0.96, and ICC3.3 = 0.90, 95% CI: 0.70 to 0.96, respectively) and moderate for the medial site (ICC3.3 = 0.89, 95% CI: 0.68 to 0.96). Interrater reliability (among investigators) was also moderate (ICC2.2 = 0.88, 95% CI: 0.73 to 0.96). Mean lower trapezius muscle thickness was approximately 3.1 mm (SD, 0.8 mm).
CONCLUSION: Thickness of the lower trapezius muscle can be measured reliably with RUSI.

Mesh:

Year:  2007        PMID: 17970409     DOI: 10.2519/jospt.2007.2446

Source DB:  PubMed          Journal:  J Orthop Sports Phys Ther        ISSN: 0190-6011            Impact factor:   4.751


  15 in total

1.  Validity of Ultrasound Imaging Versus Magnetic Resonance Imaging for Measuring Anterior Thigh Muscle, Subcutaneous Fat, and Fascia Thickness.

Authors:  Filippo Mechelli; Lars Arendt-Nielsen; Maria Stokes; Sandra Agyapong-Badu
Journal:  Methods Protoc       Date:  2019-07-10

2.  Ultrasonography for the assessment of the upper trapezius properties in healthy females: a reliability study.

Authors:  Hakimeh Adigozali; Azadeh Shadmehr; Esmail Ebrahimi; Asghar Rezasoltani; Farrokh Naderi
Journal:  Muscles Ligaments Tendons J       Date:  2016-05-19

3.  The Effects of Double Oscillation Exercise Combined with Elastic Band Exercise on Scapular Stabilizing Muscle Strength and Thickness in Healthy Young Individuals: A Randomized Controlled Pilot Trial.

Authors:  Jieun Cho; Kyeongbong Lee; Minkyu Kim; Joohee Hahn; Wanhee Lee
Journal:  J Sports Sci Med       Date:  2018-03-01       Impact factor: 2.988

4.  The reliability of rehabilitative ultrasound imaging in the measurement of infraspinatus muscle function in the symptomatic and asymptomatic shoulders of patients with unilateral shoulder impingement syndrome.

Authors:  Shane Koppenhaver; Danny Harris; Amanda Harris; Erin O'Connor; Max Dummar; Theodore Croy; Michael Walker; Tim Flynn
Journal:  Int J Sports Phys Ther       Date:  2015-04

5.  Reliability and responsiveness of musculoskeletal ultrasound in subjects with and without spinal cord injury.

Authors:  Shauna Dudley-Javoroski; Tara McMullen; Michelle R Borgwardt; Lauren M Peranich; Richard K Shields
Journal:  Ultrasound Med Biol       Date:  2010-10       Impact factor: 2.998

6.  Reliability of the Upper Trapezius Muscle and Fascia Thickness and Strain Ratio Measures by Ultrasonography and Sonoelastography in Participants With Myofascial Pain Syndrome.

Authors:  Mahyar Salavati; Behnam Akhbari; Ismail Ebrahimi Takamjani; Kamran Ezzati; Hamidreza Haghighatkhah
Journal:  J Chiropr Med       Date:  2017-10-11

7.  Functional exercise after total hip replacement (FEATHER): a randomised control trial.

Authors:  Brenda Monaghan; Tim Grant; Wayne Hing; Tara Cusack
Journal:  BMC Musculoskelet Disord       Date:  2012-11-28       Impact factor: 2.362

8.  Progressive Resistance Exercise with Eccentric Loading for the Management of Knee Osteoarthritis.

Authors:  Haniel J Hernandez; Valerie McIntosh; Azadeh Leland; Michael O Harris-Love
Journal:  Front Med (Lausanne)       Date:  2015-07-09

Review 9.  Quantitative ultrasound: measurement considerations for the assessment of muscular dystrophy and sarcopenia.

Authors:  Michael O Harris-Love; Reza Monfaredi; Catheeja Ismail; Marc R Blackman; Kevin Cleary
Journal:  Front Aging Neurosci       Date:  2014-07-14       Impact factor: 5.750

10.  Interrater reliability of quantitative ultrasound using force feedback among examiners with varied levels of experience.

Authors:  Michael O Harris-Love; Catheeja Ismail; Reza Monfaredi; Haniel J Hernandez; Donte Pennington; Paula Woletz; Valerie McIntosh; Bernadette Adams; Marc R Blackman
Journal:  PeerJ       Date:  2016-06-21       Impact factor: 2.984

View more