Literature DB >> 17969173

Tissue warming and regulatory responses induced by radio frequency energy deposition on a whole-body 3-Tesla magnetic resonance imager.

Andreas Boss1, Hansjörg Graf, Alexander Berger, Ulrike A Lauer, Hanne Wojtczyk, Claus D Claussen, Fritz Schick.   

Abstract

PURPOSE: To quantify the B1-field induced tissue warming on a 3T-whole-body scanner, to test whether the patient is able to sense the temperature change, and to evaluate whether the imaging procedure constitutes a significant cardiovascular stress.
MATERIALS AND METHODS: A total of 18 volunteers were divided into three equal groups for 3.0T MRI of the pelvis, the head, or the knee. An imaging protocol operating at first level mode was applied, allowing radio frequency (RF) irradiation up to the legal specific absorption rate (SAR) limits. An identical placebo protocol with active gradient switching but without RF transmission was used. Temperature changes were measured with a fiber-optic thermometer (FO) and an infrared camera (IR).
RESULTS: Temperature differences to the placebo were highest for imaging of the pelvis (FO: DeltaT = 0.88 +/- 0.13 degrees C, IR: DeltaT = 1.01 +/- 0.15 degrees C) as compared to the head (FO: DeltaT = 0.46 +/- 0.12 degrees C, IR: DeltaT = 0.47 +/- 0.10 degrees C) and the knee (FO: DeltaT = 0.33 +/- 0.11 degrees C, IR: DeltaT = 0.37 +/- 0.09 degrees C). The volunteers were able to discriminate between imaging and placebo for pelvic (P < 0.0001) and head (P = 0.0005) imaging but not for knee imaging (P = 0.209). No changes in heart rate or blood pressure were detected.
CONCLUSION: The 3.0T MRI in the first operational mode may lead to measurable and perceptible thermal energy deposition. However, it may be regarded as safe concerning the thermoregulatory cardiovascular stress.

Entities:  

Mesh:

Year:  2007        PMID: 17969173     DOI: 10.1002/jmri.21156

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  11 in total

1.  Wave-CAIPI susceptibility-weighted imaging achieves diagnostic performance comparable to conventional susceptibility-weighted imaging in half the scan time.

Authors:  Mi Sun Chung; Eun Jung Lee; Sujin Kim; Seon-Ok Kim; Jun Soo Byun
Journal:  Eur Radiol       Date:  2020-01-17       Impact factor: 5.315

2.  In vivo radiofrequency heating in swine in a 3T (123.2-MHz) birdcage whole body coil.

Authors:  Devashish Shrivastava; Lynn Utecht; Jinfeng Tian; John Hughes; J Thomas Vaughan
Journal:  Magn Reson Med       Date:  2013-11-20       Impact factor: 4.668

3.  Spinal cord lesions and clinical status in multiple sclerosis: A 1.5 T and 3 T MRI study.

Authors:  J M Stankiewicz; M Neema; D C Alsop; B C Healy; A Arora; G J Buckle; T Chitnis; C R G Guttmann; D Hackney; R Bakshi
Journal:  J Neurol Sci       Date:  2009-04-15       Impact factor: 3.181

4.  Brain MRI lesion load at 1.5T and 3T versus clinical status in multiple sclerosis.

Authors:  James M Stankiewicz; Bonnie I Glanz; Brian C Healy; Ashish Arora; Mohit Neema; Ralph H B Benedict; Zachary D Guss; Shahamat Tauhid; Guy J Buckle; Maria K Houtchens; Samia J Khoury; Howard L Weiner; Charles R G Guttmann; Rohit Bakshi
Journal:  J Neuroimaging       Date:  2011-04       Impact factor: 2.486

Review 5.  Magnetic resonance safety.

Authors:  Steffen Sammet
Journal:  Abdom Radiol (NY)       Date:  2016-03

6.  Normal findings on brain fluid-attenuated inversion recovery MR images at 3T.

Authors:  M Neema; Z D Guss; J M Stankiewicz; A Arora; B C Healy; R Bakshi
Journal:  AJNR Am J Neuroradiol       Date:  2009-04-15       Impact factor: 3.825

7.  Combined acquisition technique (CAT) for neuroimaging of multiple sclerosis at low specific absorption rates (SAR).

Authors:  Armin Biller; Morwan Choli; Martin Blaimer; Felix A Breuer; Peter M Jakob; Andreas J Bartsch
Journal:  PLoS One       Date:  2014-03-07       Impact factor: 3.240

8.  Investigation of Factors Affecting Body Temperature Changes During Routine Clinical Head Magnetic Resonance Imaging.

Authors:  Myeong Seong Kim
Journal:  Iran J Radiol       Date:  2016-07-04       Impact factor: 0.212

9.  A prospective observational study to evaluate the magnitude of temperature changes in children undergoing elective MRI under general anesthesia.

Authors:  Merlin S Ruth; Nivetha Sridharan; Ekta Rai; Anita S Joselyn
Journal:  Saudi J Anaesth       Date:  2020-03-05

Review 10.  Physiological recordings: basic concepts and implementation during functional magnetic resonance imaging.

Authors:  Marcus A Gray; Ludovico Minati; Neil A Harrison; Peter J Gianaros; Vitaly Napadow; Hugo D Critchley
Journal:  Neuroimage       Date:  2009-05-19       Impact factor: 6.556

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.