Literature DB >> 17969117

Three-dimensional spiral technique for high-resolution functional MRI.

Yanle Hu1, Gary H Glover.   

Abstract

For high-resolution functional MRI (fMRI) studies, signal-to-noise ratio (SNR) plays an important role. Any method that results in an improvement in SNR will be able to improve the quality of activation maps. Three-dimensional (3D) acquisition methods in general can provide higher SNR than that of 2D methods due to volume excitation. To demonstrate the superiority of 3D methods for high-resolution fMRI scans, a comparison study between 3D and 2D spiral methods was performed using a contrast-reversing checkerboard visual stimulus. A 3-inch surface coil was used to limit the in-plane FOV to 14 cm x 14 cm so that 32 1-mm slices with an in-plane voxel size of 1.1 mm x 1.1 mm could be acquired within 5.76 seconds. Results showed that average numbers of activated voxels were 407 and 841 for 2D and 3D methods, respectively (P < 0.01). Therefore, the 3D technique may be a useful alternative to the conventional 2D method for high resolution fMRI studies. Copyright 2007 Wiley-Liss, Inc.

Mesh:

Year:  2007        PMID: 17969117     DOI: 10.1002/mrm.21328

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  16 in total

Review 1.  Spiral imaging in fMRI.

Authors:  Gary H Glover
Journal:  Neuroimage       Date:  2011-10-20       Impact factor: 6.556

2.  Three dimensional echo-planar imaging at 7 Tesla.

Authors:  B A Poser; P J Koopmans; T Witzel; L L Wald; M Barth
Journal:  Neuroimage       Date:  2010-02-06       Impact factor: 6.556

3.  Enhancement of temporal resolution and BOLD sensitivity in real-time fMRI using multi-slab echo-volumar imaging.

Authors:  Stefan Posse; Elena Ackley; Radu Mutihac; Jochen Rick; Matthew Shane; Cristina Murray-Krezan; Maxim Zaitsev; Oliver Speck
Journal:  Neuroimage       Date:  2012-02-28       Impact factor: 6.556

4.  Temporal SNR characteristics in segmented 3D-EPI at 7T.

Authors:  W van der Zwaag; J P Marques; T Kober; G Glover; R Gruetter; G Krueger
Journal:  Magn Reson Med       Date:  2011-06-07       Impact factor: 4.668

5.  Variable-density spiral-in/out functional magnetic resonance imaging.

Authors:  Catie Chang; Gary H Glover
Journal:  Magn Reson Med       Date:  2010-11-30       Impact factor: 4.668

6.  Fast and tissue-optimized mapping of magnetic susceptibility and T2* with multi-echo and multi-shot spirals.

Authors:  Bing Wu; Wei Li; Alexandru Vlad Avram; Sung-Min Gho; Chunlei Liu
Journal:  Neuroimage       Date:  2011-07-19       Impact factor: 6.556

7.  Three dimensional radial echo planar imaging for functional MRI.

Authors:  Christoph A Rettenmeier; Danilo Maziero; V Andrew Stenger
Journal:  Magn Reson Med       Date:  2021-08-19       Impact factor: 4.668

8.  Rotated stack-of-spirals partial acquisition for rapid volumetric parallel MRI.

Authors:  Weiran Deng; Benjamin Zahneisen; V Andrew Stenger
Journal:  Magn Reson Med       Date:  2015-08-13       Impact factor: 4.668

9.  Development, validation, and comparison of ICA-based gradient artifact reduction algorithms for simultaneous EEG-spiral in/out and echo-planar fMRI recordings.

Authors:  S Ryali; G H Glover; C Chang; V Menon
Journal:  Neuroimage       Date:  2009-07-04       Impact factor: 6.556

Review 10.  Rapid brain MRI acquisition techniques at ultra-high fields.

Authors:  Kawin Setsompop; David A Feinberg; Jonathan R Polimeni
Journal:  NMR Biomed       Date:  2016-02-02       Impact factor: 4.044

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.