Literature DB >> 17969027

Non-Cartesian data reconstruction using GRAPPA operator gridding (GROG).

Nicole Seiberlich1, Felix A Breuer, Martin Blaimer, Kestutis Barkauskas, Peter M Jakob, Mark A Griswold.   

Abstract

A novel approach that uses the concepts of parallel imaging to grid data sampled along a non-Cartesian trajectory using GRAPPA operator gridding (GROG) is described. GROG shifts any acquired data point to its nearest Cartesian location, thereby converting non-Cartesian to Cartesian data. Unlike other parallel imaging methods, GROG synthesizes the net weight for a shift in any direction from a single basis set of weights along the logical k-space directions. Given the vastly reduced size of the basis set, GROG calibration and reconstruction requires fewer operations and less calibration data than other parallel imaging methods for gridding. Instead of calculating and applying a density compensation function (DCF), GROG requires only local averaging, as the reconstructed points fall upon the Cartesian grid. Simulations are performed to demonstrate that the root mean square error (RMSE) values of images gridded with GROG are similar to those for images gridded using the gold-standard convolution gridding. Finally, GROG is compared to the convolution gridding technique using data sampled along radial, spiral, rosette, and BLADE (a.k.a. periodically rotated overlapping parallel lines with enhanced reconstruction [PROPELLER]) trajectories. (c) 2007 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2007        PMID: 17969027     DOI: 10.1002/mrm.21435

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  37 in total

1.  Combination of compressed sensing and parallel imaging for highly accelerated first-pass cardiac perfusion MRI.

Authors:  Ricardo Otazo; Daniel Kim; Leon Axel; Daniel K Sodickson
Journal:  Magn Reson Med       Date:  2010-09       Impact factor: 4.668

2.  RT-GROG: parallelized self-calibrating GROG for real-time MRI.

Authors:  Haris Saybasili; J Andrew Derbyshire; Peter Kellman; Mark A Griswold; Cengizhan Ozturk; Robert J Lederman; Nicole Seiberlich
Journal:  Magn Reson Med       Date:  2010-07       Impact factor: 4.668

3.  A radial self-calibrated (RASCAL) generalized autocalibrating partially parallel acquisition (GRAPPA) method using weight interpolation.

Authors:  Noel C F Codella; Pascal Spincemaille; Martin Prince; Yi Wang
Journal:  NMR Biomed       Date:  2010-12-28       Impact factor: 4.044

4.  The Role of Nonlinear Gradients in Parallel Imaging: A k-Space Based Analysis.

Authors:  Gigi Galiana; Jason P Stockmann; Leo Tam; Dana Peters; Hemant Tagare; R Todd Constable
Journal:  Concepts Magn Reson Part A Bridg Educ Res       Date:  2012-09-26       Impact factor: 0.481

5.  Improvements in multislice parallel imaging using radial CAIPIRINHA.

Authors:  Stephen R Yutzy; Nicole Seiberlich; Jeffrey L Duerk; Mark A Griswold
Journal:  Magn Reson Med       Date:  2011-02-01       Impact factor: 4.668

6.  Algebraic reconstruction technique for parallel imaging reconstruction of undersampled radial data: application to cardiac cine.

Authors:  Shu Li; Cheong Chan; Jason P Stockmann; Hemant Tagare; Ganesh Adluru; Leo K Tam; Gigi Galiana; R Todd Constable; Sebastian Kozerke; Dana C Peters
Journal:  Magn Reson Med       Date:  2014-04-18       Impact factor: 4.668

7.  Parallel Magnetic Resonance Imaging as Approximation in a Reproducing Kernel Hilbert Space.

Authors:  Vivek Athalye; Michael Lustig; Martin Uecker
Journal:  Inverse Probl       Date:  2015-04-01       Impact factor: 2.407

Review 8.  State-of-the-art MRI techniques in neuroradiology: principles, pitfalls, and clinical applications.

Authors:  Magalie Viallon; Victor Cuvinciuc; Benedicte Delattre; Laura Merlini; Isabelle Barnaure-Nachbar; Seema Toso-Patel; Minerva Becker; Karl-Olof Lovblad; Sven Haller
Journal:  Neuroradiology       Date:  2015-04-10       Impact factor: 2.804

9.  A GRAPPA algorithm for arbitrary 2D/3D non-Cartesian sampling trajectories with rapid calibration.

Authors:  Tianrui Luo; Douglas C Noll; Jeffrey A Fessler; Jon-Fredrik Nielsen
Journal:  Magn Reson Med       Date:  2019-05-03       Impact factor: 4.668

10.  Self-calibrated trajectory estimation and signal correction method for robust radial imaging using GRAPPA operator gridding.

Authors:  Anagha Deshmane; Martin Blaimer; Felix Breuer; Peter Jakob; Jeffrey Duerk; Nicole Seiberlich; Mark Griswold
Journal:  Magn Reson Med       Date:  2015-03-11       Impact factor: 4.668

View more