The figure-of-four axis as a reference to determine stem rotation in hip arthroplasty. What does it really measure? A cadaver study.

Eckart Mayr1, Martin Thaler, Alexandra Williams, Jose Moctezuma de La Barrera, Martin Krismer, Michael Nogler.   

Abstract

BACKGROUND AND
PURPOSE: Implantation of the femoral component at 10-15 degrees of anteversion is recommended in THA. Surgical guidelines suggest that the lower leg be positioned horizontally or vertically with the knee flexed to 90 degrees (figure of four). By constructing a perpendicular axis (a "figure-of-four" axis) to the lower leg, anteversion of the stem is approximated. We assessed whether the figure-of-four axis is a reliable intraoperative tool to approximate the retrocondylar line as a reference for stem version.
METHODS: Cadavers (21 in total) were placed supine on an operating table and the lower legs were aligned to the horizontal plane. Cannulated titanium screws were inserted perpendicular to the lower leg into the medial epicondyle, representing the figure-of-four axis. The femoral neck axes, retrocondylar lines, and the figure-of-four axes were determined using CT images of the specimen.
RESULTS: The anteversion of the femoral neck was median 9.8 (4.5-15.1) degrees (interquartile range). The figure-of-four axis deviated by 0.5 (-2.1-2) degrees, whereas the median difference in the axis in relation to the femoral neck axis was 9.5 (-13.6 to -2) degrees.
INTERPRETATION: The figure-of-four axis, being nearly parallel to the retrocondylar line, is a valid indirect method for determination of stem version intraoperatively in patients without varus/valgus deviations of the knee.

Entities:  

Mesh:

Year:  2007        PMID: 17965998     DOI: 10.1080/17453670710014086

Source DB:  PubMed          Journal:  Acta Orthop        ISSN: 1745-3674            Impact factor:   3.717


  4 in total

1.  Comparison of clinical results and patient's satisfaction between direct anterior approach and Hardinge approach in primary total hip arthroplasty in a community hospital.

Authors:  C Trevisan; R Compagnoni; R Klumpp
Journal:  Musculoskelet Surg       Date:  2017-04-27

2.  Effect of femoral neck modularity upon the prosthetic range of motion in total hip arthroplasty.

Authors:  Glen A Turley; Damian R Griffin; Mark A Williams
Journal:  Med Biol Eng Comput       Date:  2014-06-27       Impact factor: 2.602

3.  Validation of the femoral anteversion measurement method used in imageless navigation.

Authors:  Glen A Turley; Shahbaz M Y Ahmed; Mark A Williams; Damian R Griffin
Journal:  Comput Aided Surg       Date:  2012-06-08

Review 4.  Hemiarthroplasty of the hip using the direct anterior approach.

Authors:  Michael Nogler; Filippo Randelli; George A Macheras; Martin Thaler
Journal:  Oper Orthop Traumatol       Date:  2021-08-03       Impact factor: 1.154

  4 in total