Literature DB >> 17964398

Ocular aberrations and contrast sensitivity after cataract surgery with AcrySof IQ intraocular lens implantation Clinical comparative study.

Patrick F Tzelikis1, Leonardo Akaishi, Fernando C Trindade, Joel E Boteon.   

Abstract

PURPOSE: To determine whether implantation of an intraocular lens (IOL) with a modified posterior aspherical surface (AcrySof IQ, Alcon Surgical Laboratories) results in reduced ocular aberrations (spherical aberration) and improved contrast sensitivity after cataract surgery.
SETTING: Brasilia Ophthalmologic Hospital, Brasilia, and Sao Geraldo Eye Hospital, Federal University of Minas Gerais, Belo Horizonte, Brazil.
METHODS: In an intraindividual randomized prospective study of 25 patients with bilateral cataract, an IOL with a modified posterior surface (AcrySof IQ) was compared with a biconvex IOL with spherical surfaces (AcrySof Natural, Alcon). Ocular aberrations with a 5.0 mm and 6.0 mm pupil were measured with a Hartmann-Shack aberrometer. Quality of vision was measured by visual acuity and contrast sensitivity under mesopic and photopic conditions. All patients were followed for 3 months.
RESULTS: There were no statistically significant differences between eyes in postoperative uncorrected and best corrected distance visual acuities after a follow-up of 1 month and 3 months. Postoperatively, there was a statistically significant between-group difference in contrast sensitivity under photopic conditions without glare at 18 cycles per degree (cpd) (P = .04) and under mesopic conditions without glare at all spatial frequencies (3 cpd, 6 cpd, 12 cpd, and 18 cpd; P = .03, P = .009, P = .003, and P = .003, respectively) and with glare at 3 cpd and 6 cpd (P = .001 and P = .02, respectively). The difference in higher-order aberration (HOA) values between groups was statistically significant with a 5.0 mm and 6.0 mm pupil, with the AcrySof IQ IOL inducing less HOA than the AcrySof Natural IOL. Eyes with an AcrySof IQ IOL also had statistically significant less spherical aberration than eyes with an AcrySof Natural IOL with both pupil diameters (P<.001).
CONCLUSIONS: The AcrySof IQ IOL with a modified posterior surface induced significantly less HOA and spherical aberration than the AcrySof Natural IOL. Contrast sensitivity was better under mesopic conditions with the AcrySof IQ IOL.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17964398     DOI: 10.1016/j.jcrs.2007.06.053

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  13 in total

1.  Comparison of contrast sensitivity, depth of field and ocular wavefront aberrations in eyes with an IOL with zero versus positive spherical aberration.

Authors:  Jay S Pepose; Mujtaba A Qazi; Keith H Edwards; Jeff P Sanderson; Edwin J Sarver
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2009-03-11       Impact factor: 3.117

2.  [Aberration corrected intraocular lens for microincision cataract surgery (MICS). Intraindividual comparison with a conventional lens - 1-year follow-up].

Authors:  M Möglich; H Häberle; D T Pham; C Wirbelauer
Journal:  Ophthalmologe       Date:  2009-10       Impact factor: 1.059

3.  Improvement of neural contrast sensitivity after long-term adaptation in pseudophakic eyes.

Authors:  Seung Pil Bang; Justin D Aaker; Ramkumar Sabesan; Geunyoung Yoon
Journal:  Biomed Opt Express       Date:  2022-08-03       Impact factor: 3.562

4.  Tilt and decentration of an intraocular lens implanted in the ciliary sulcus after capsular bag defect during cataract surgery.

Authors:  Thomas Sauer; Ulrich Mester
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-09-02       Impact factor: 3.117

Review 5.  [Aspheric intraocular lenses].

Authors:  T Kohnen; O K Klaproth
Journal:  Ophthalmologe       Date:  2008-03       Impact factor: 1.174

6.  Contrast sensitivity and spherical aberration in eyes implanted with AcrySof IQ and AcrySof Natural intraocular lens: the results of a meta-analysis.

Authors:  Jianping Liu; Jiangyue Zhao; Liwei Ma; Guangcong Liu; Di Wu; Jinsong Zhang
Journal:  PLoS One       Date:  2013-10-18       Impact factor: 3.240

7.  A comparative study on visual and optical performance of Akreos AO and Kontur AB IOLs after phacoemulsification cataract surgery.

Authors:  Hamid Gharaee; Masoud Zabihifard; Alireza Eslampour; Samira Hassanzadeh; Masoud Shafiee
Journal:  J Curr Ophthalmol       Date:  2016-03-28

8.  Higher order aberrations in a normal adult population.

Authors:  Hassan Hashemi; Mehdi Khabazkhoob; Ebrahim Jafarzadehpur; Abbasali Yekta; Mohammad Hassan Emamian; Mohammad Shariati; Akbar Fotouhi
Journal:  J Curr Ophthalmol       Date:  2016-01-05

9.  Aspheric intraocular lenses implantation for cataract patients with extreme myopia.

Authors:  Yanwen Fang; Yi Lu; Aizhu Miao; Yi Luo
Journal:  ISRN Ophthalmol       Date:  2014-03-19

10.  Visual Restoration after Cataract Surgery Promotes Functional and Structural Brain Recovery.

Authors:  Haotian Lin; Li Zhang; Duoru Lin; Wan Chen; Yi Zhu; Chuan Chen; Kevin C Chan; Yizhi Liu; Weirong Chen
Journal:  EBioMedicine       Date:  2018-03-07       Impact factor: 8.143

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.