Literature DB >> 17963958

Evaluation of the surface characteristics of used and new ProTaper Instruments: an atomic force microscopy study.

Ugur Inan1, Cumhur Aydin, Ozgur Uzun, Ozgur Topuz, Tayfun Alacam.   

Abstract

The purpose of this study was to evaluate the topography of new and used ProTaper rotary nickel-titanium (NiTi) instruments by using atomic force microscope. Four new and four used size S1, S2, F1, and F2 instruments were selected for this study. New and used instruments were analyzed on 11 points along a 3-mm section at the tip of the instrument. Quantitative measurements according to the topographic deviations (root mean square) were recorded. Data were analyzed by paired samples t test. Mean root mean square values for used ProTaper instruments were higher than the new ones, and the difference between them was statistically significant. The results of this study showed that used ProTaper instruments demonstrated more surface deformation and wear.

Mesh:

Substances:

Year:  2007        PMID: 17963958     DOI: 10.1016/j.joen.2007.07.014

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  7 in total

1.  The effect of multiple autoclave cycles on the surface of rotary nickel-titanium endodontic files: An in vitro atomic force microscopy investigation.

Authors:  Ashish Shashikant Nair; Mahima Tilakchand; Balaram Damodar Naik
Journal:  J Conserv Dent       Date:  2015 May-Jun

2.  The effect of 5% sodium hypochlorite, 17% EDTA and triphala on two different rotary Ni-Ti instruments: An AFM and EDS analysis.

Authors:  Pramod Siva Prasad; Jonathan Emi Sam; Arvind Kumar
Journal:  J Conserv Dent       Date:  2014-09

3.  Antibacterial nanosilver coated orthodontic bands with potential implications in dentistry.

Authors:  Rahul Damodaran Prabha; Rajasigamani Kandasamy; U Sajeev Sivaraman; Maya A Nandkumar; Prabha D Nair
Journal:  Indian J Med Res       Date:  2016-10       Impact factor: 2.375

4.  Effect of Autoclave Cycles on Surface Characteristics of S-File Evaluated by Scanning Electron Microscopy.

Authors:  Hamid Razavian; Pedram Iranmanesh; Hamid Mojtahedi; Rahman Nazeri
Journal:  Iran Endod J       Date:  2015-12-24

5.  The effect of root canal preparation on the surface roughness of WaveOne and WaveOne Gold files: atomic force microscopy study.

Authors:  Taha Özyürek; Koray Yılmaz; Gülşah Uslu; Gianluca Plotino
Journal:  Restor Dent Endod       Date:  2018-02-02

6.  A new method for assessment of nickel-titanium endodontic instrument surface roughness using field emission scanning electronic microscope.

Authors:  Khoa Van Pham; Canh Quang Vo
Journal:  BMC Oral Health       Date:  2020-08-31       Impact factor: 2.757

Review 7.  Metallurgical Tests in Endodontics: A Narrative Review.

Authors:  Alessio Zanza; Marco Seracchiani; Rodolfo Reda; Gabriele Miccoli; Luca Testarelli; Dario Di Nardo
Journal:  Bioengineering (Basel)       Date:  2022-01-12
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.