Literature DB >> 17961765

A simple and rapid immunochromatographic test strip for detection of pathogenic isolates of Vibrio harveyi.

Paisarn Sithigorngul1, Sombat Rukpratanporn, Nilawan Pecharaburanin, Pornthip Suksawat, Siwaporn Longyant, Parin Chaivisuthangkura, Weerawan Sithigorngul.   

Abstract

Mouse monoclonal antibodies (MAbs) and rabbit polyclonal antibody (PAb) against Vibrio harveyi were generated from immunization of mice and rabbits with highly virulent isolate of V. harveyi. Two MAbs specific to virulent isolates of V. harveyi were obtained and one of them (VH4) was selected to conjugate with colloidal gold as the detector antibody was laid on a sample pad. Rabbit polyclonal antibody was used as the capture antibody at the test line (T) and goat anti-mouse IgG antibody (GAM) was used as the capture antibody at the control line (C) of nitrocellulose strip. The ready-to-use strip was held in a plastic case and then stored in a desiccated plastic bag. A sample volume of 100 microl of bacterial suspension from various sources mixed with application buffer was applied to the sample chamber at one end of the strip and allowed to flow by chromatography through the nitrocellulose membrane to the other end. In test samples containing virulent isolates of V. harveyi, the bacteria would bind to the monoclonal antibody conjugated with colloidal gold and the resulting complex would be captured by the antibodies at the test line to give a reddish-purple band. Any unbound monoclonal antibody conjugated with colloidal gold moved across the test line would be captured by the GAM and form a band at the control line (C). In sample without V. harveyi or with V. harveyi below the limit (<10(6) CFU/ml) of detection for the kit, only the control line band was observed. If the test sample was pre-enriched in tryptic soy broth (TSB) for 6 h before application to the strip, the sensitivity would increase to 1-10 CFU/ml which is comparable to that of PCR. This method could be used to detect pathogenic isolates of V. harveyi in pond water or infected shrimp in order to monitor and to reduce the risk of V. harveyi outbreak in the shrimp culture. The beneficial features of this kit are that simple, convenient and quick results (within 15 min) can be obtained without the requirement of sophisticated tools or special equipments and skills.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17961765     DOI: 10.1016/j.mimet.2007.09.012

Source DB:  PubMed          Journal:  J Microbiol Methods        ISSN: 0167-7012            Impact factor:   2.363


  3 in total

1.  An Indigenous, Field-Deployable, Lateral Flow Immunochromatographic Assay Rapidly Detects Infectious Myonecrosis in Shrimp, Litopenaeus vannamei.

Authors:  S Santhosh Kumar; Snehal Jamalpure; A Nafeez Ahmed; G Taju; S Vimal; S Abdul Majeed; S Suryakodi; Syed Rahamathulla; Kishore M Paknikar; Jyutika M Rajwade; A S Sahul Hameed
Journal:  Mar Biotechnol (NY)       Date:  2022-10-15       Impact factor: 3.727

2.  Lateral flow test strip based on colloidal selenium immunoassay for rapid detection of melamine in milk, milk powder, and animal feed.

Authors:  Zhizeng Wang; Dejuan Zhi; Yang Zhao; Hailong Zhang; Xin Wang; Yi Ru; Hongyu Li
Journal:  Int J Nanomedicine       Date:  2014-04-03

3.  Development of a colloidal gold kit for the diagnosis of severe fever with thrombocytopenia syndrome virus infection.

Authors:  Xianguo Wang; Quanfu Zhang; Fen Hao; Xunian Gao; Wei Wu; Minyao Liang; Zhihua Liao; Shuhong Luo; Weiwen Xu; Dexin Li; Shiwen Wang
Journal:  Biomed Res Int       Date:  2014-04-14       Impact factor: 3.411

  3 in total