Literature DB >> 17960655

Kinematic analysis of kneeling in cruciate-retaining and posterior-stabilized total knee arthroplasties.

Satoshi Hamai1, Hiromasa Miura, Hidehiko Higaki, Shuichi Matsuda, Takeshi Shimoto, Kousuke Sasaki, Masaaki Yoshizumi, Ken Okazaki, Nobuaki Tsukamoto, Yukihide Iwamoto.   

Abstract

Kneeling is an important function of the knee for many activities of daily living. In this study, we evaluated the in vivo kinematics of kneeling after total knee arthroplasty (TKA) using radiographic based image-matching techniques. Kneeling from 90 to 120 degrees of knee flexion produced a posterior femoral rollback after both cruciate-retaining and posterior-stabilized TKA. It could be assumed that the posterior cruciate ligament and the post-cam mechanism were functioning. The posterior-stabilized TKA design had contact regions located far posterior on the tibial insert in comparison to the cruciate-retaining TKA. Specifically, the lateral femoral condyle in posterior-stabilized TKA translated to the posterior edge of the tibial surface, although there was no finding of subluxation. After posterior-stabilized TKA, the contact position of the post-cam translated to the posterior medial corner of the post with external rotation of the femoral component. Because edge loading can induce accelerated polyethylene wear, the configuration of the post-cam mechanism should be designed to provide a larger contact area when the femoral component rotates. c) 2007 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2008        PMID: 17960655     DOI: 10.1002/jor.20512

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  15 in total

1.  Ligament tension in the ACL-deficient knee: assessment of medial and lateral gaps.

Authors:  David Mayman; Christopher Plaskos; Daniel Kendoff; G Wernecke; Andrew D Pearle; Richard Laskin
Journal:  Clin Orthop Relat Res       Date:  2009-02-24       Impact factor: 4.176

2.  In vivo knee kinematics during high flexion after a posterior-substituting total knee arthroplasty.

Authors:  Angela L Moynihan; Kartik M Varadarajan; George R Hanson; Sang-Eun Park; Kyung Wook Nha; Jeremy F Suggs; Todd Johnson; Guoan Li
Journal:  Int Orthop       Date:  2009-04-22       Impact factor: 3.075

3.  Patellofemoral kinematics during deep knee flexion after total knee replacement: a computational simulation.

Authors:  Chang-Hung Huang; Lin-I Hsu; Kun-Jhih Lin; Ting-Kuo Chang; Cheng-Kung Cheng; Yung-Chang Lu; Chen-Sheng Chen; Chun-Hsiung Huang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-01-03       Impact factor: 4.342

4.  Classical target coronal alignment in high tibial osteotomy demonstrates validity in terms of knee kinematics and kinetics in a computer model.

Authors:  Shinichi Kuriyama; Mutsumi Watanabe; Shinichiro Nakamura; Kohei Nishitani; Kazuya Sekiguchi; Yoshihisa Tanaka; Hiromu Ito; Shuichi Matsuda
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2019-06-21       Impact factor: 4.342

5.  Correlation between preoperative and postoperative knee kinematics in total knee arthroplasty using cruciate retaining designs.

Authors:  Jong Keun Seon; Ju Kwon Park; Mun Su Jeong; Woo Bin Jung; Kyung Soon Park; Taek Rim Yoon; Eun Kyoo Song
Journal:  Int Orthop       Date:  2010-04-30       Impact factor: 3.075

6.  Is the posterior cruciate ligament necessary for medial pivot knee prostheses with regard to postoperative kinematics?

Authors:  Chao-Hua Fang; Chia-Ming Chang; Yu-Shu Lai; Wen-Chuan Chen; Da-Yong Song; Colin J McClean; Hao-Yuan Kao; Tie-Bing Qu; Cheng-Kung Cheng
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-08-26       Impact factor: 4.342

7.  Influence of component design on in vivo tibiofemoral contact patterns during kneeling after total knee arthroplasty: a systematic review and meta-analysis.

Authors:  Joseph T Lynch; Jennie M Scarvell; Catherine R Galvin; Paul N Smith; Diana M Perriman
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2020-04-03       Impact factor: 4.342

8.  Are undesirable contact kinematics minimized after kinematically aligned total knee arthroplasty? An intersurgeon analysis of consecutive patients.

Authors:  Stephen M Howell; Esther E Hodapp; Joseph V Vernace; Maury L Hull; Thomas D Meade
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-10-02       Impact factor: 4.342

9.  Kinematics of hip, knee, ankle of the young and elderly Chinese people during kneeling activity.

Authors:  Hai Zhou; Dong-mei Wang; Tao-ran Liu; Xiang-sen Zeng; Cheng-tao Wang
Journal:  J Zhejiang Univ Sci B       Date:  2012-10       Impact factor: 3.066

10.  No influence of coronal laxity and alignment on lift-off after well-balanced and aligned total knee arthroplasty.

Authors:  Satoshi Hamai; Hiromasa Miura; Ken Okazaki; Takeshi Shimoto; Hidehiko Higaki; Yukihide Iwamoto
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-04-17       Impact factor: 4.342

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.