Literature DB >> 17960336

Transabdominal ultrasonography, computed tomography and electronic portal imaging for 3-dimensional conformal radiotherapy for prostate cancer.

Barbara Alicja Jereczek-Fossa1, Federica Cattani, Cristina Garibaldi, Dario Zerini, Raffaella Cambria, Genoveva Ionela Boboc, Marco Valenti, Anna Kowalczyk, Andrea Vavassori, Giovanni Battista Ivaldi, Mario Ciocca, Deliu Victor Matei, Ottavio De Cobelli, Roberto Orecchia.   

Abstract

PURPOSE: To evaluate the feasibility and accuracy of daily B-mode acquisition and targeting ultrasound-based prostate localization (BAT) and to compare it with computed tomography (CT) and electronic portal imaging (EPI) in 3-dimensional conformal radiotherapy (3-D CRT) for prostate cancer. PATIENTS AND METHODS: Ten patients were treated with 3-D CRT (72 Gy/30 fractions, 2.4 Gy/fraction, equivalent to 80 Gy/40 fractions, for alpha/beta ratio of 1.5 Gy) and daily BAT-based prostate localization. For the first 5 fractions, CT and EPI were also performed in order to compare organ-motion and set-up error, respectively.
RESULTS: 287 BAT-, 50 CT- and 46 EPI-alignments were performed. The average BAT-determined misalignments in latero-lateral, antero-posterior and cranio-caudal directions were -0.9 mm+/-3.3 mm, 1.0 mm+/-4.0 mm and -0.9 mm+/-3.8 mm, respectively. The differences between BAT- and CT-determined organ-motion in latero-lateral, antero-posterior and cranio-caudal directions were 2.7 mm+/-1.9 mm, 3.9+/-2.8 mm and 3.4 +/- 3.0 mm, respectively. Weak correlation was found between BAT- and CT-determined misalignments in antero-posterior direction, while no correlation was observed in latero-lateral and cranio-caudal directions. The correlation was more significant when only data of good image-quality patients were analyzed (8 patients).
CONCLUSION: BAT ensures the relative positions of target are the same during treatment and in treatment plan, however, the reliability of alignment is patient-dependent. The average BAT-determined misalignments were small, confirming the prevalence of random errors in 3-D CRT. Further study is warranted in order to establish the clinical value of BAT.

Entities:  

Mesh:

Year:  2007        PMID: 17960336     DOI: 10.1007/s00066-007-1702-5

Source DB:  PubMed          Journal:  Strahlenther Onkol        ISSN: 0179-7158            Impact factor:   3.621


  17 in total

1.  Numerical deconvolution to enhance sharpness and contrast of portal images for radiotherapy patient positioning verification.

Authors:  H K Looe; Y Uphoff; D Harder; B Poppe; K C Willborn
Journal:  Strahlenther Onkol       Date:  2012-01-12       Impact factor: 3.621

2.  Abstracts of the 1st International Conference on the Clinical Use of Tomotherapy. October 17-18, 2008. Munich, Germany.

Authors: 
Journal:  Strahlenther Onkol       Date:  2009-01       Impact factor: 3.621

3.  Physical and clinical implications of radiotherapy treatment of prostate cancer using a full bladder protocol.

Authors:  Raffaella Cambria; Barbara A Jereczek-Fossa; Dario Zerini; Federica Cattani; Flavia Serafini; Rosa Luraschi; Guido Pedroli; Roberto Orecchia
Journal:  Strahlenther Onkol       Date:  2011-11-25       Impact factor: 3.621

4.  External-beam radiotherapy for clinically localized prostate cancer in Osaka, Japan, 1995-2006: time trends, outcome, and risk stratification.

Authors:  Yasuo Yoshioka; Osamu Suzuki; Kana Kobayashi; Teruki Teshima; Yuji Yamada; Tadayuki Kotsuma; Masahiko Koizumi; Kazufumi Kagawa; Masashi Chatani; Shigetoshi Shimamoto; Eiichi Tanaka; Hideya Yamazaki; Takehiro Inoue
Journal:  Strahlenther Onkol       Date:  2009-08-28       Impact factor: 3.621

Review 5.  Hypofractionated radiotherapy for localised prostate cancer. Review of clinical trials.

Authors:  Víctor Macías; Albert Biete
Journal:  Clin Transl Oncol       Date:  2009-07       Impact factor: 3.405

6.  Using cone-beam computed tomography to evaluate the impact of bladder filling status on target position in prostate radiotherapy.

Authors:  Chiao-Ling Tsai; Jian-Kuen Wu; Chun-Wei Wang; Feng-Ming Hsu; Ming-Kuen Lai; Jason Chia-Hsien Cheng
Journal:  Strahlenther Onkol       Date:  2009-09-12       Impact factor: 3.621

7.  Dosimetric comparison of image guidance by megavoltage computed tomography versus bone alignment for prostate cancer radiotherapy.

Authors:  Jörn Kalz; Florian Sterzing; Kai Schubert; Gabriele Sroka-Perez; Jürgen Debus; Klaus Herfarth
Journal:  Strahlenther Onkol       Date:  2009-04-16       Impact factor: 3.621

8.  A randomized trial comparing hypofractionated and conventionally fractionated three-dimensional external-beam radiotherapy for localized prostate adenocarcinoma : a report on acute toxicity.

Authors:  Darius Norkus; Albert Miller; Juozas Kurtinaitis; Uwe Haverkamp; Sergey Popov; Franz-Josef Prott; Konstantinas Povilas Valuckas
Journal:  Strahlenther Onkol       Date:  2009-11-10       Impact factor: 3.621

9.  A strategy for the use of image-guided radiotherapy (IGRT) on linear accelerators and its impact on treatment margins for prostate cancer patients.

Authors:  Olaf Nairz; Florian Merz; Heinz Deutschmann; Peter Kopp; Helmut Schöller; Franz Zehentmayr; Karl Wurstbauer; Gerhard Kametriser; Felix Sedlmayer
Journal:  Strahlenther Onkol       Date:  2008-12-24       Impact factor: 3.621

10.  Image-guided radiotherapy for prostate cancer. Implementation of ultrasound-based prostate localization for the analysis of inter- and intrafraction organ motion.

Authors:  Michael Pinkawa; Martin Pursch-Lee; Branka Asadpour; Bernd Gagel; Marc D Piroth; Jens Klotz; Sandra Nussen; Michael J Eble
Journal:  Strahlenther Onkol       Date:  2008-12-24       Impact factor: 3.621

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.