INTRODUCTION: Traditional advanced imaging modalities such as CT and MRI are limited in their ability to perform accurate linear distance and angular measurements regardless of anatomical orientation. The construction of 3D models has been used to perform anthropometric analyses as well as in the reconstruction of rapid prototypes. We hypothesized that such measurements would be precise to within 2 mm or 2 degrees of measurements performed with a coordinate measurement machine (CMM). We also hypothesized that there would be a high degree of interobserver reliability with these measurements.
MATERIALS AND METHODS: Multiple aluminum screws were implanted in various positions in three foam pelvises which were subsequently scanned by CT and rendered as 3D models using a commercially available software package (Mimics). Linear and angular measurements were performed using a CMM machine, the software package, and a dial caliper or goniometer. The deviation of the measurements from the CMM data was compared using ANOVA. The interobserver reliability of both the manual and computer-generated measurements was calculated.
RESULTS: The mean difference between the CMM distances and those measured manually and with the software was 2.12 +/- 1.20 mm and 1.57 +/- 1.05 mm, respectively. The mean difference between the CMM angular measurements and the angular measurements performed manually and with the software was 4.07 +/- 4.70 degrees and 1.62 +/- 1.32 degrees, respectively. In all cases, the manual measurements were significantly less accurate (p < 0.0001) and there was a high degree of interobserver reliability.
CONCLUSIONS: Computer-generated measurements taken from three-dimensionally reconstructed models are more accurate than manual measurements and are within 2 mm and 2 degrees of measurements performed with a CMM. These measurements have high interobserver reliability.

Entities:  

Mesh:

Year:  2007        PMID: 17957535     DOI: 10.3109/10929080701680265

Source DB:  PubMed          Journal:  Comput Aided Surg        ISSN: 1092-9088


  10 in total

1.  Multilevel measurement of acetabular version using 3-D CT-generated models: implications for hip preservation surgery.

Authors:  Aimee C Perreira; John C Hunter; Thaddeus Laird; Amir A Jamali
Journal:  Clin Orthop Relat Res       Date:  2010-09-25       Impact factor: 4.176

2.  Femoral anteversion in THA and its lack of correlation with native acetabular anteversion.

Authors:  William L Bargar; Amir A Jamali; Amir H Nejad
Journal:  Clin Orthop Relat Res       Date:  2009-08-28       Impact factor: 4.176

Review 3.  Three-dimensional reconstructions in spine and screw trajectory simulation on 3D digital images: a step by step approach by using Mimics software.

Authors:  Dong Chen; Chun-Hui Chen; Li Tang; Kai Wang; Yu-Zhe Li; Kevin Phan; Ai-Min Wu
Journal:  J Spine Surg       Date:  2017-12

4.  Measurement accuracy of a computer-assisted three-dimensional analysis and a conventional two-dimensional method.

Authors:  Huseyin Olmez; Serkan Gorgulu; Erol Akin; Ali Osman Bengi; Ibrahim Tekdemir; Fatih Ors
Journal:  Angle Orthod       Date:  2011-01-24       Impact factor: 2.079

5.  Pelvimetry by Three-Dimensional Computed Tomography in Non-Pregnant Multiparous Women Who Delivered Vaginally.

Authors:  Ismail Salk; Ali Cetin; Sultan Salk; Meral Cetin
Journal:  Pol J Radiol       Date:  2016-05-08

6.  Suprascapular notch morphology in the pediatric population: a computed tomography study.

Authors:  M Podgórski; M Polguj; M Topol; A Kusak; M Łukaszewski; P Grzelak
Journal:  Anat Sci Int       Date:  2016-08-18       Impact factor: 1.741

Review 7.  Do small changes in rotation affect measurements of lower extremity limb alignment?

Authors:  Amir A Jamali; John P Meehan; Nathan M Moroski; Matthew J Anderson; Ramit Lamba; Carol Parise
Journal:  J Orthop Surg Res       Date:  2017-05-22       Impact factor: 2.359

8.  Three-Dimensional Changes of Maxilla after Secondary Alveolar Cleft Repair: Differences Between rhBMP-2 and Autologous Iliac Crest Bone Grafting.

Authors:  Cassio Eduardo Raposo-Amaral; Rafael Denadai; Nivaldo Alonso
Journal:  Plast Reconstr Surg Glob Open       Date:  2015-08-10

9.  A reliable radiographic measurement for evaluation of normal distal tibiofibular syndesmosis: a multi-detector computed tomography study in adults.

Authors:  Yanxi Chen; Minfei Qiang; Kun Zhang; Haobo Li; Hao Dai
Journal:  J Foot Ankle Res       Date:  2015-07-25       Impact factor: 2.303

10.  Measurement of three-dimensional morphological characteristics of the calcaneus using CT image post-processing.

Authors:  Minfei Qiang; Yanxi Chen; Kun Zhang; Haobo Li; Hao Dai
Journal:  J Foot Ankle Res       Date:  2014-03-14       Impact factor: 2.303

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.