Literature DB >> 17952796

Asbestos release from whole-building demolition of buildings with asbestos-containing material.

Robert A Perkins1, John Hargesheimer, Walter Fourie.   

Abstract

The whole-building demolition method, which entails one-or two-story buildings pushed down by heavy equipment, loaded into trucks, and hauled away, is generally the most cost-effective means to remove small buildings. For taller buildings, a crane and wrecking ball may be used initially to reduce the height of the building. Demolitions might release asbestos fibers from friable asbestos-containing material (ACM). Fibers also might be released from nominally nonfriable ACM (Categories I and II nonfriable ACM) if it becomes friable after rough handling throughout the whole-building demolition process. This paper reports on asbestos air monitoring from two demolition projects involving ACM. In one building, Category II nonfriable ACM was present because it could not be removed safely prior to demolition. Both projects had large quantities of gypsum wallboard with ACM joint compound and ACM flooring. One building had large quantities of ACM spray-on ceiling material. During the demolitions personal air monitoring of the workers and area air monitoring downwind and around the sites were conducted. The monitoring found the concentrations of fibers detected by phase contrast microscopy were generally well below the permissible exposure limits (PEL) of workers. Electron microcopy analysis of samples at or near the PEL indicated most of the fibers were not asbestos, and the actual asbestos exposure was often below the detection limit of the procedure. The buildings were kept wet with fire hoses during the demolition and that required large quantities of water, 20,000-60,000 gal/day (75-225 m(3)/day). Earlier studies found little asbestos release from buildings containing only nonfriable ACM demolished by this method. This project found a negligible release of asbestos fibers, despite the presence of nonfriable materials that might become friable, such as ACM joint compound and spray-on ACM ceiling coating.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17952796     DOI: 10.1080/15459620701691023

Source DB:  PubMed          Journal:  J Occup Environ Hyg        ISSN: 1545-9624            Impact factor:   2.155


  7 in total

1.  Asbestos-containing materials in abandoned residential dwellings in Detroit.

Authors:  A Franzblau; A H Demond; S K Sayler; H D'Arcy; R L Neitzel
Journal:  Sci Total Environ       Date:  2020-01-10       Impact factor: 7.963

2.  Framework for assessment and phytoremediation of asbestos-contaminated sites.

Authors:  Cédric Gonneau; Kinsey Miller; Sanjay K Mohanty; Rengyi Xu; Wei-Ting Hwang; Jane K Willenbring; Brenda B Casper
Journal:  Environ Sci Pollut Res Int       Date:  2017-09-22       Impact factor: 4.223

3.  Measurement of asbestos emissions associated with demolition of abandoned residential dwellings.

Authors:  Richard L Neitzel; Stephanie K Sayler; Avery H Demond; Hannah d'Arcy; David H Garabrant; Alfred Franzblau
Journal:  Sci Total Environ       Date:  2020-03-21       Impact factor: 7.963

4.  The natural reduction of threat in selected systems of old buildings containing asbestos.

Authors:  Andrzej Obmiński
Journal:  Sci Rep       Date:  2022-02-16       Impact factor: 4.379

Review 5.  Microbiomes, Epigenomics, Immune Response, and Splicing Signatures Interplay: Potential Use of Combination of Regulatory Pathways as Targets for Malignant Mesothelioma.

Authors:  Botle Precious Setlai; Zilungile Lynette Mkhize-Kwitshana; Ravi Mehrotra; Thanyani Victor Mulaudzi; Zodwa Dlamini
Journal:  Int J Mol Sci       Date:  2022-08-12       Impact factor: 6.208

6.  Asbestos exposure among construction workers during demolition of old houses in Tehran, Iran.

Authors:  Hossein Kakooei; Mohhammad Normohammadi
Journal:  Ind Health       Date:  2013-11-29       Impact factor: 2.179

7.  Estimating the Additional Greenhouse Gas Emissions in Korea: Focused on Demolition of Asbestos Containing Materials in Building.

Authors:  Young-Chan Kim; Won-Hwa Hong; Yuan-Long Zhang; Byeung-Hun Son; Youn-Kyu Seo; Jun-Ho Choi
Journal:  Int J Environ Res Public Health       Date:  2016-09-12       Impact factor: 3.390