Literature DB >> 17946544

A multiscale tracking algorithm for the coronary extraction in MSCT angiography.

G Yang1, A Bousse, C Toumoulin, H Shu.   

Abstract

This paper deals with the extraction of the coronary network on dynamic volume sequences, acquired in multi-slice spiral computed tomography (MSCT). The proposed approach makes use of a tracking algorithm of the vascular structure, combining a 3D geometric moment operator with a multiscale Hessian filter to estimate the vessel central axis location, its local diameter and orientation. The method performs at the same time, a bifurcation detection to reconstitute the structure of the coronary network. The mean computation time to extract a coronary network is about 3 minutes using a P4-2.4G PC. Preliminary encouraging results are presented on one volume of a sequence.

Mesh:

Year:  2006        PMID: 17946544      PMCID: PMC2075537          DOI: 10.1109/IEMBS.2006.260712

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  3 in total

1.  Model-based quantitation of 3-D magnetic resonance angiographic images.

Authors:  A F Frangi; W J Niessen; R M Hoogeveen; T van Walsum; M A Viergever
Journal:  IEEE Trans Med Imaging       Date:  1999-10       Impact factor: 10.048

2.  A 3D Static Heart Model From a MSCT Data Set.

Authors:  G Yang; C Toumoulin; J-L Coatrieux; H Shu; L Luo; D Boulmier
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2005

3.  A 3-D moment based approach for blood vessel detection and quantification in MRA.

Authors:  P Reuzé; J L Coatrieux; L M Luo; J L Dillenseger
Journal:  Technol Health Care       Date:  1993-01-01       Impact factor: 1.285

  3 in total
  7 in total

1.  ECG gated tomographic reconstruction for 3-D rotational coronary angiography.

Authors:  Yining Hu; Lizhe Xie; Jean Claude Nunes; Jean Jacques Bellanger; Marc Bedossa; Christine Toumoulin
Journal:  Annu Int Conf IEEE Eng Med Biol Soc       Date:  2010

2.  Simulation environment for the evaluation of 3D coronary tree reconstruction algorithms in rotational angiography.

Authors:  G Yang; A Bousse; C Toumoulin; H Shu
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2007

3.  Motion compensated tomography reconstruction of coronary arteries in rotational angiography.

Authors:  Alexandre Bousse Ast; Jian Zhou; Guanyu Yang; Jean-Jacques Bellanger; Christine Toumoulin
Journal:  IEEE Trans Biomed Eng       Date:  2008-10-14       Impact factor: 4.538

4.  Liver vessels segmentation using a hybrid geometrical moments/graph cuts method.

Authors:  Simon Esneault; Cyril Lafon; Jean-Louis Dillenseger
Journal:  IEEE Trans Biomed Eng       Date:  2009-09-25       Impact factor: 4.538

5.  Characterization of 3-D coronary tree motion from MSCT angiography.

Authors:  Guanyu Yang; Jian Zhou; Dominique Boulmier; Marie-Paule Garcia; Limin Luo; Christine Toumoulin
Journal:  IEEE Trans Inf Technol Biomed       Date:  2009-09-25

6.  Standardized evaluation methodology and reference database for evaluating coronary artery centerline extraction algorithms.

Authors:  Michiel Schaap; Coert T Metz; Theo van Walsum; Alina G van der Giessen; Annick C Weustink; Nico R Mollet; Christian Bauer; Hrvoje Bogunović; Carlos Castro; Xiang Deng; Engin Dikici; Thomas O'Donnell; Michel Frenay; Ola Friman; Marcela Hernández Hoyos; Pieter H Kitslaar; Karl Krissian; Caroline Kühnel; Miguel A Luengo-Oroz; Maciej Orkisz; Orjan Smedby; Martin Styner; Andrzej Szymczak; Hüseyin Tek; Chunliang Wang; Simon K Warfield; Sebastian Zambal; Yong Zhang; Gabriel P Krestin; Wiro J Niessen
Journal:  Med Image Anal       Date:  2009-06-30       Impact factor: 8.545

7.  Diagnostic value of ultrasound score, color Doppler ultrasound RI and spiral CT for ovarian tumors.

Authors:  Li Zhou; Zhidong Xuan; Yu Wang
Journal:  Oncol Lett       Date:  2019-04-04       Impact factor: 2.967

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.