Evaluation of surgical energy devices for vessel sealing and peripheral energy spread in a porcine model.

Gregory W Hruby1, Franzo C Marruffo, Evren Durak, Sean M Collins, Phillip Pierorazio, Peter A Humphrey, Mahesh M Mansukhani, Jaime Landman.   

Abstract

PURPOSE: Vessel sealing capabilities and the peripheral energy spread associated with currently available energy based surgical instruments were evaluated.
MATERIALS AND METHODS: Four groups of energy based surgical instruments were established for evaluation, including the ACE, LCS-C5 (Ethicon, Cincinnati, Ohio), LigaSure V and the prototype Trissector. In vivo vessel diameter under physiological conditions, bursting pressures and seal failure were recorded and analyzed for arteries and veins separately. After burst testing the vessels were fixed and evaluated histopathologically for peripheral energy damage. ANOVA was used to determine differences between groups.
RESULTS: The LigaSure V sealed arteries and veins with an average burst pressure of 536 and 386 mm Hg, respectively. The Harmonic ACE sealed arteries and veins with an average burst pressure of 436 and 160 mm Hg, respectively. The Harmonic LCS-C5 sealed arteries and veins with an average burst pressure of 363 and 215 mm Hg, respectively. The Trissector sealed arteries and veins with an average burst pressure of 328 and 237 mm Hg, respectively. For arteries the ACE, LCS-C5, Trissector and LigaSure V measured a full-thickness peripheral energy spread of 0.6, 0.3, 8.0 and 4.5 mm, respectively (p <0.0001). For veins the ACE, LCS-C5, Trissector and LigaSure V measured a full-thickness peripheral energy spread of 1.5, 1.3, 8.5 and 6.3 mm, respectively (p = 0.003).
CONCLUSIONS: The LigaSure 5 was superior to the other devices tested regarding the ability to seal vessels up to 7 mm. The ACE is an efficient vessel sealing system with the ability to seal vessels up to 5 mm.

Entities:  

Mesh:

Year:  2007        PMID: 17945280     DOI: 10.1016/j.juro.2007.07.121

Source DB:  PubMed          Journal:  J Urol        ISSN: 0022-5347            Impact factor:   7.450


  27 in total

1.  Perpendicular blood vessel seals are stronger than those made at an angle.

Authors:  Aaron C Voegele; Donna L Korvick; Mario Gutierrez; Jeffrey W Clymer; Joseph F Amaral
Journal:  J Laparoendosc Adv Surg Tech A       Date:  2013-06-11       Impact factor: 1.878

2.  Collagen-elastin ratio predicts burst pressure of arterial seals created using a bipolar vessel sealing device in a porcine model.

Authors:  David Sindram; Kimberly Martin; Jarrod P Meadows; Ajita S Prabhu; Jessica J Heath; Iain H McKillop; David A Iannitti
Journal:  Surg Endosc       Date:  2011-03-15       Impact factor: 4.584

3.  Tissue storage ex vivo significantly increases vascular fusion bursting pressure.

Authors:  James D Cezo; Eric A Kramer; Jonathan A Schoen; Virginia L Ferguson; Kenneth D Taylor; Mark E Rentschler
Journal:  Surg Endosc       Date:  2014-10-16       Impact factor: 4.584

4.  Lateral thermal spread induced by energy devices: a porcine model to evaluate the influence on the recurrent laryngeal nerve.

Authors:  Masaru Hayami; Masayuki Watanabe; Shinji Mine; Yu Imamura; Akihiko Okamura; Masami Yuda; Kotaro Yamashita; Tasuku Toihata; Yoshiaki Shoji; Naoki Ishizuka
Journal:  Surg Endosc       Date:  2019-03-07       Impact factor: 4.584

5.  Surface-processing technology of a microgrooving and water-repellent coating improves the fusion potential of an ultrasonic energy device.

Authors:  Satoru Okada; Junichi Shimada; Kazuhiro Ito; Tatsuo Ishii; Koichiro Oshiumi
Journal:  Surg Endosc       Date:  2016-06-22       Impact factor: 4.584

6.  A multi-physics model for ultrasonically activated soft tissue.

Authors:  Rahul Suvranu De
Journal:  Comput Methods Appl Mech Eng       Date:  2017-02-01       Impact factor: 6.756

7.  Optical coherence tomography for use in infrared laser sealing of blood vessels.

Authors:  Nicholas C Giglio; Thomas C Hutchens; Christopher M Cilip; Nathaniel M Fried
Journal:  IEEE Photonics Conf       Date:  2020-11-16

8.  Athermal versus ultrasonic nerve-sparing laparoscopic radical prostatectomy: a comparison of functional and oncological outcomes.

Authors:  Vincenzo Pagliarulo; Stefano Alba; Maria Filomena Gallone; Marcello Zingarelli; Alfonso Lorusso; Paolo Minafra; Giuseppe Maria Ludovico; Savino Di Stasi; Pasquale Ditonno
Journal:  World J Urol       Date:  2020-08-01       Impact factor: 4.226

9.  Implementation of a novel efficacy score to compare sealing and cutting devices in a porcine model.

Authors:  Lea Brecht; Markus Wallwiener; Sarah Schott; Christoph Domschke; Christine Dinkic; Michael Golatta; Florian Schuetz; Herbert Fluhr; Albrecht Stenzinger; Marietta Kirchner; Christof Sohn; Joachim Rom
Journal:  Surg Endosc       Date:  2017-08-24       Impact factor: 4.584

Review 10.  Update on Surgical Principles and Equipment.

Authors:  Kevin T Kroner; Casey Budgeon; Sara A Colopy
Journal:  Vet Clin North Am Exot Anim Pract       Date:  2016-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.