Literature DB >> 17944662

Cardiac MRI: accuracy of simultaneous measurement of left and right ventricular parameters using three different sequences.

Juha W Koskenvuo1, Henna Karra, Jaakko Lehtinen, Pekka Niemi, Jussi Pärkkä, Juhani Knuuti, Jaakko J Hartiala.   

Abstract

BACKGROUND AND AIM: We evaluated a value of Qp/Qs (left-to-right shunt measurement) using volumetric cardiac magnetic resonance (CMR) cardiac output (CO) measurements. We defined intraobserver, interobserver variability and reproducibility of left and right ventricular parameters by CMR. Furthermore, we studied whether shortened acquisition time has an effect on the accuracy of left and right ventricular parameters both in healthy volunteers and in patients with cardiovascular disease.
METHODS: Sixteen subjects were enrolled in this study. Group A (n = 8, five males) consisted of healthy volunteers with a mean age of 25.9 years (range 24-30). Group B (n = 8, four males) was heterogenic consisting of patients with left ventricular (LV) hypertrophy, hypertension or coronary artery disease with their mean age of 56.3 years (range 38-70).
RESULTS: The measured Qp/Qs as calculated from the right and LV CO was 0.87 +/- 0.13. Overall variability [as presented with the lowest coefficient of variation (CV)%- the highest CV % of intraobserver, interobserver variability or reproducibility] of LV parameters were for ejection fraction (EF) 1.5-2.8%, stroke volume (SV) 1.3-3.2%, CO 1.4-3.2%, end-diastolic volume 0.5-3.0%, end-systolic volume 1.8-6.2% and LV mass 1.1-2.6%. Corresponding values for right ventricular parameters were for EF 1.1-4.2%, SV 1.9-8.2%, CO 1.9-7.6%, end-diastolic volume 2.1-7.6%, end-systolic volume 2.8-10.2% and right ventricle mass 2.9-8.3%. There was no statistically significant difference between the results of different sequences.
CONCLUSIONS: The CMR allows accurate Qp/Qs observation but the absolute value is at slightly different level compared with reference methods. Both left and right ventricular parameters are highly reproducible and even small clinically relevant changes can be measured with CMR. The shortened acquisition does not affect significantly to the accuracy of CMR-derived parameters.

Entities:  

Mesh:

Year:  2007        PMID: 17944662     DOI: 10.1111/j.1475-097X.2007.00764.x

Source DB:  PubMed          Journal:  Clin Physiol Funct Imaging        ISSN: 1475-0961            Impact factor:   2.273


  9 in total

Review 1.  Imaging congenital heart disease in adults.

Authors:  P J Kilner
Journal:  Br J Radiol       Date:  2011-12       Impact factor: 3.039

2.  Quantitative analysis of cardiac left ventricular variables obtained by MRI at 3 T: a pre- and post-contrast comparison.

Authors:  S Matthew; S J Gandy; R S Nicholas; S A Waugh; E A Crowe; R A Lerski; M H Dunn; J G Houston
Journal:  Br J Radiol       Date:  2012-07       Impact factor: 3.039

3.  Gated blood pool SPECT: The estimation of right ventricular volume and function is algorithm dependent in a clinical setting.

Authors:  Laurent Dercle; Monia Ouali; Pierre Pascal; Thomas Giraudmaillet; Roland Chisin; Olivier Lairez; Marie-Agnès Marachet; Hervé Rousseau; Delphine Bastié; Fayçal Ben Bouallègue; Isabelle Berry
Journal:  J Nucl Cardiol       Date:  2015-02-20       Impact factor: 5.952

4.  Myocardial glucose uptake in patients with the m.3243A > G mutation in mitochondrial DNA.

Authors:  Markus M Lindroos; Jussi P Pärkkä; Markku T Taittonen; Patricia Iozzo; Mikko Kärppä; Ilmo E Hassinen; Juhani Knuuti; Pirjo Nuutila; Kari Majamaa
Journal:  J Inherit Metab Dis       Date:  2015-06-26       Impact factor: 4.982

5.  Improved estimation of the cardiac global function using combined long and short axis MRI images of the heart.

Authors:  Hossam El-Rewaidy; Ahmed S Fahmy
Journal:  Biomed Eng Online       Date:  2016-04-27       Impact factor: 2.819

6.  Cardiac Function, Perfusion, Metabolism, and Innervation following Autologous Stem Cell Therapy for Acute ST-Elevation Myocardial Infarction. A FINCELL-INSIGHT Sub-Study with PET and MRI.

Authors:  Maija T Mäki; Juha W Koskenvuo; Heikki Ukkonen; Antti Saraste; Helena Tuunanen; Mikko Pietilä; Sergey V Nesterov; Ville Aalto; K E Juhani Airaksinen; Jussi P Pärkkä; Riikka Lautamäki; Kari Kervinen; Johanna A Miettinen; Timo H Mäkikallio; Matti Niemelä; Marjaana Säily; Pirjo Koistinen; Eeva-Riitta Savolainen; Kari Ylitalo; Heikki V Huikuri; Juhani Knuuti
Journal:  Front Physiol       Date:  2012-01-30       Impact factor: 4.566

7.  Manual correction of semi-automatic three-dimensional echocardiography is needed for right ventricular assessment in adults; validation with cardiac magnetic resonance.

Authors:  Ellen Ostenfeld; Marcus Carlsson; Kambiz Shahgaldi; Anders Roijer; Johan Holm
Journal:  Cardiovasc Ultrasound       Date:  2012-01-06       Impact factor: 2.062

8.  Twenty-four-month alpha-galactosidase A replacement therapy in Fabry disease has only minimal effects on symptoms and cardiovascular parameters.

Authors:  J W Koskenvuo; J J Hartiala; P Nuutila; R Kalliokoski; J S Viikari; E Engblom; M Penttinen; J Knuuti; I Mononen; I M Kantola
Journal:  J Inherit Metab Dis       Date:  2008-05-23       Impact factor: 4.750

9.  Systemic Dosing of Thymosin Beta 4 before and after Ischemia Does Not Attenuate Global Myocardial Ischemia-Reperfusion Injury in Pigs.

Authors:  Christoffer K-J Stark; Miikka Tarkia; Rasmus Kentala; Markus Malmberg; Tommi Vähäsilta; Matti Savo; Ville-Veikko Hynninen; Mikko Helenius; Saku Ruohonen; Juho Jalkanen; Pekka Taimen; Tero-Pekka Alastalo; Antti Saraste; Juhani Knuuti; Timo Savunen; Juha Koskenvuo
Journal:  Front Pharmacol       Date:  2016-05-03       Impact factor: 5.810

  9 in total