Literature DB >> 17924899

A comparison of the disposable vs the reusable laryngeal tube in paralysed adult patients.

A Amini1, F Zand, S E Sadeghi.   

Abstract

A disposable laryngeal tube (LT-D) with dimensions identical to, but physical properties different from (stiffer tube/thicker cuff), the reusable laryngeal tube (LT-R) has recently become available. We performed a randomised, single blind trial among 100 anaesthetised and paralysed patients to compare these devices in terms of ease of insertion, airway sealing pressure, position assessed fibreoptically and postoperative throat complications. Anaesthesia was administered with midazolam, fentanyl, propofol, atracurium, oxygen and isoflurane. The LT-D and LT-R showed similar clinical performances, as shown by their insertion times (28.4 and 23.6 s, respectively). Successful insertion at the first attempt was achieved in 90% with LT-D and 96% with LT-R. There were no differences in airway sealing pressure, fibreoptic position or post operative sore throat and dysphagia. The intra cuff pressure remained stable for the LT-R but decreased slightly for the LT-D. In paralysed, anaesthetised patients, the single use and reusable laryngeal tubes are similar in clinical performance.

Entities:  

Mesh:

Year:  2007        PMID: 17924899     DOI: 10.1111/j.1365-2044.2007.05196.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  4 in total

1.  The laryngeal tube - a helpful tool for cardiopulmonary resuscitation in the dental office?

Authors:  G Keilholz; T S Mutzbauer
Journal:  Br Dent J       Date:  2015-05-08       Impact factor: 1.626

2.  Randomized evaluation of the size 2 laryngeal tube and classical laryngeal mask airway in different head and neck positions in children under positive pressure ventilation.

Authors:  Andreas Biedler; Marc Wrobel; Sven Schneider; Stefan Soltész; Stephan Ziegeler; Ulrich Grundmann
Journal:  J Anesth       Date:  2013-03-04       Impact factor: 2.078

Review 3.  Insertion Success of the Laryngeal Tube in Emergency Airway Management.

Authors:  Michael Bernhard; André Gries; Alexandra Ramshorn-Zimmer; Volker Wenzel; Bjoern Hossfeld
Journal:  Biomed Res Int       Date:  2016-08-24       Impact factor: 3.411

Review 4.  A Literature Review of Factors Related to Postoperative Sore Throat.

Authors:  Yuta Mitobe; Yuri Yamaguchi; Yasuko Baba; Tomomi Yoshioka; Kenji Nakagawa; Takeshi Itou; Kiyoyasu Kurahashi
Journal:  J Clin Med Res       Date:  2022-02-24
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.