Literature DB >> 17924214

Influence of the target vessel on the location and area of maximum skin dose during percutaneous coronary intervention.

K Chida1, K Fuda, Y Kagaya, H Saito, Y Takai, M Kohzuki, S Takahashi, S Yamada, M Zuguchi.   

Abstract

BACKGROUND: A number of cases involving radiation-associated patient skin injury attributable to percutaneous coronary intervention (PCI) have been reported. Knowledge of the location and area of the patient's maximum skin dose (MSD) in PCI is necessary to reduce the risk of skin injury.
PURPOSE: To determine the location and area of the MSD in PCI, and separately analyze the effects of different target vessels.
MATERIAL AND METHODS: 197 consecutive PCI procedures were studied, and the location and area of the MSD were calculated by a skin-dose mapping software program: Caregraph. The target vessels of the PCI procedures were divided into four groups based on the American Heart Association (AHA) classification.
RESULTS: The sites of the MSD for AHA #1-3, AHA #4, and AHA #11-15 were located mainly on the right back skin, the lower right or center back skin, and the upper back skin areas, respectively, whereas the MSD sites for the AHA #5-10 PCI were widely spread. The MSD area for the AHA #4 PCI was larger than that for the AHA #11-15 PCI (P<0.0001).
CONCLUSION: Although the radiation associated with PCI can be widely spread and variable, we observed a tendency regarding the location and area of the MSD when we separately analyzed the data for different target vessels. We recommend the use of a smaller radiation field size and the elimination of overlapping fields during PCI.

Entities:  

Mesh:

Year:  2007        PMID: 17924214     DOI: 10.1080/02841850701468875

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  2 in total

1.  Effectiveness of a New Lead-Shielding Device and Additional Filter for Reducing Staff and Patient Radiation Exposure During Videofluoroscopic Swallowing Study Using a Human Phantom.

Authors:  Yoshiaki Morishima; Koichi Chida; Yoshikazu Muroya; Yoshiya Utsumi
Journal:  Dysphagia       Date:  2017-09-18       Impact factor: 3.438

2.  Evaluating the performance of a MOSFET dosimeter at diagnostic X-ray energies for interventional radiology.

Authors:  Koichi Chida; Youhei Inaba; Hanako Masuyama; Isao Yanagawa; Issei Mori; Haruo Saito; Shin Maruoka; Masayuki Zuguchi
Journal:  Radiol Phys Technol       Date:  2008-11-15
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.