Literature DB >> 17923153

Quantitative determination of radio-opacity: equivalence of digital and film X-ray systems.

R Nomoto1, A Mishima, K Kobayashi, J F McCabe, B W Darvell, D C Watts, Y Momoi, S Hirano.   

Abstract

OBJECTIVES: To evaluate the equivalence of a digital X-ray system (DenOptix) to conventional X-ray film in terms of the measured radio-opacity of known filled-resin materials and the suitability of attenuation coefficient for radio-opacity determination.
METHODS: Discs of five thicknesses (0.5-2.5mm) and step-wedges of each of three composite materials of nominal aluminum-equivalence of 50%, 200% and 450% were used. X-ray images of a set of discs (or step-wedge), an aluminum step-wedge, and a lead block were taken at 65 kV and 10 mA at a focus-film distance of 400 mm for 0.15s and 1.6s using an X-ray film or imaging plate. Radio-opacity was determined as equivalent aluminum thickness and attenuation coefficient. The logarithm of the individual optical density or gray scale value, corrected for background, was plotted against thickness, and the attenuation coefficient determined from the slope. The method of ISO 4049 was used for equivalent aluminum thickness.
RESULTS: The equivalent aluminum thickness method is not suitable for materials of low radio-opacity, while the attenuation coefficient method could be used for all without difficulty. The digital system gave attenuation coefficients of greater precision than did film, but the use of automatic gain control (AGC) distorted the outcome unusably.
CONCLUSION: Attenuation coefficient is a more precise and generally applicable approach to the determination of radio-opacity. The digital system was equivalent to film but with less noise. The use of AGC is inappropriate for such determinations.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17923153     DOI: 10.1016/j.dental.2007.08.005

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  13 in total

1.  Radiopacity of dental restorative materials.

Authors:  Tomaž Hitij; Aleš Fidler
Journal:  Clin Oral Investig       Date:  2012-07-24       Impact factor: 3.573

2.  A comparative study on diagnostic accuracy of colour coded digital images, direct digital images and conventional radiographs for periapical lesions - an in vitro study.

Authors:  Abhishek Ranjan Pati; Vijayalakshmi K R; Sanat Kumar Bhuyan; Rajat G Panigrahi; Smita R Priyadarshini; Satyaranjan Misra; Chandravir Singh
Journal:  J Clin Diagn Res       Date:  2014-11-20

3.  How does duration of curing affect the radiopacity of dental materials?

Authors:  Arash Poorsattar Bejeh Mir; Morvarid Poorsattar Bejeh Mir
Journal:  Imaging Sci Dent       Date:  2012-06-25

4.  A daptomycin-xylitol-loaded polymethylmethacrylate bone cement: how much xylitol should be used?

Authors:  Ali Salehi; Ashley Cox Parker; Gladius Lewis; Harry S Courtney; Warren O Haggard
Journal:  Clin Orthop Relat Res       Date:  2013-10       Impact factor: 4.176

5.  Radiopacity evaluation of composite restorative resins and bonding agents using digital and film x-ray systems.

Authors:  Bengi Oztas; Sebnem Kursun; Gul Dinc; Kıvanc Kamburoglu
Journal:  Eur J Dent       Date:  2012-04

6.  Evaluation of radiopacities of CAD/CAM restorative materials and resin cements by digital radiography.

Authors:  Zerrin Unal Erzurumlu; Cennet Elcin Sagirkaya; Kerem Erzurumlu
Journal:  Clin Oral Investig       Date:  2021-03-11       Impact factor: 3.606

7.  The effects of image acquisition control of digital X-ray system on radiodensity quantification.

Authors:  Wook-Jin Seong; Hyeon-Cheol Kim; Soocheol Jeong; Youngcheul Heo; Woo-Bin Song; Mansur Ahmad
Journal:  Restor Dent Endod       Date:  2013-08-23

8.  Assessment of radiopacity of restorative composite resins with various target distances and exposure times and a modified aluminum step wedge.

Authors:  Arash Poorsattar Bejeh Mir; Morvarid Poorsattar Bejeh Mir
Journal:  Imaging Sci Dent       Date:  2012-09-21

9.  Radiopacity of restorative composites by conventional radiograph and digital images with different resolutions.

Authors:  Raquel Venâncio Fernandes Dantas; Hugo Ramalho Sarmento; Rosângela Marques Duarte; Sônia Saeger Meireles Monte Raso; Ana Karina Maciel de Andrade; Maria Luiza Dos Anjos-Pontual
Journal:  Imaging Sci Dent       Date:  2013-09-23

10.  The effect of hydrogen gas evolution of magnesium implant on the postimplantation mortality of rats.

Authors:  Deni Noviana; Devi Paramitha; Mokhamad Fakhrul Ulum; Hendra Hermawan
Journal:  J Orthop Translat       Date:  2015-08-20       Impact factor: 5.191

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.