The level of cardiac output affects the relationship and agreement between pulmonary artery and transpulmonary aortic thermodilution measurements in an animal model.

Lars Hüter1, Konrad R Schwarzkopf, Niels P Preussler, Harald Schubert, Torsten Schreiber.   

Abstract

OBJECTIVE: The authors investigated the relationship between pulmonary artery and transpulmonary aortic thermodilution cardiac output measurements under conditions of increasing cardiac output (CO).
DESIGN: Animal study with repeated simultaneous measurements comparing 2 cardiac output measurement techniques.
SETTING: Experimental animal facility of a university hospital. PARTICIPANTS: Ten female pigs.
INTERVENTIONS: In anesthetized pigs, an aortic thermistor catheter and a pulmonary artery catheter (PAC) were inserted. Then dobutamine was infused under continuous cardiac output (CCO) monitoring to target different levels of CO. After each L/min increase of CCO simultaneous aortic and PAC thermodilution, CO measurements were performed by using a bolus injection of cooled normal saline and the amount of thermal indicator loss (TL) was calculated.
MEASUREMENTS AND MAIN RESULTS: Pooled analysis of CO data with the method of Bland and Altman showed that aortic thermodilution CO was higher than PAC thermodilution CO with a bias of 3.8% +/- 11.1%. The range of TL was 30.4% to -10.1%. Differential analysis according to the range of CO revealed that, in each animal under conditions of low CO, aortic thermodilution CO was higher than PAC thermodilution CO, whereas results were inverse under conditions of high CO.
CONCLUSIONS: The authors concluded that the amount of CO differentially affects the relationship between aortic and PAC thermodilution CO. TL and recirculation may be the explanation for this finding.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17905270     DOI: 10.1053/j.jvca.2007.01.005

Source DB:  PubMed          Journal:  J Cardiothorac Vasc Anesth        ISSN: 1053-0770            Impact factor:   2.628


  5 in total

1.  Comparison of cardiovascular parameter estimation methods using swine data.

Authors:  Tatsuya Arai; Kichang Lee; Richard J Cohen
Journal:  J Clin Monit Comput       Date:  2019-05-18       Impact factor: 2.502

2.  Stroke volume determination using transcardiopulmonary thermodilution and arterial pulse contour analysis in severe aortic valve disease.

Authors:  Martin Petzoldt; Carsten Riedel; Jan Braeunig; Sebastian Haas; Matthias S Goepfert; Hendrik Treede; Stephan Baldus; Alwin E Goetz; Daniel A Reuter
Journal:  Intensive Care Med       Date:  2013-01-04       Impact factor: 17.440

3.  Reliability of transcardiopulmonary thermodilution cardiac output measurement in experimental aortic valve insufficiency.

Authors:  Martin Petzoldt; Constantin J Trepte; Jan Ridder; Stefan Maisch; Philipp Klapsing; Jan F Kersten; Hans Peter Richter; Jens C Kubitz; Daniel A Reuter; Matthias S Goepfert
Journal:  PLoS One       Date:  2017-10-19       Impact factor: 3.240

4.  Comparison of monitoring performance of Bioreactance vs. pulse contour during lung recruitment maneuvers.

Authors:  Pierre Squara; Dominique Rotcajg; Dominique Denjean; Philippe Estagnasie; Alain Brusset
Journal:  Crit Care       Date:  2009-07-28       Impact factor: 9.097

5.  Macrocirculatory Parameters and Oxygen Debt Indices in Pigs During Propofol Or Alfaxalone Anesthesia When Subjected to Experimental Stepwise Hemorrhage.

Authors:  Andreas Lervik; Simen Forr Toverud; Jon Bohlin; Henning Andreas Haga
Journal:  Front Vet Sci       Date:  2021-05-20
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.