Literature DB >> 17904887

Measuring statistical agreement between four point of care (POC) lactate meters and a laboratory blood analyzer in cats.

Mark J Acierno1, Meghan E Johnson, Lee Ann Eddleman, Mark A Mitchell.   

Abstract

The use of blood lactate concentrations as a prognostic indicator and therapeutic gauge in feline medicine has been hindered by the inability to obtain values in a timely manner with minimal quantities of blood. Recently, hand-held point-of-care (POC) lactate meters have become commercially available. The objective of this prospective study was to determine if lactate values produced by three commercially available and one medical grade POC meter were in agreement with a laboratory blood analyzer. Blood samples from 47 cats were collected on presentation to an emergency service and processed on four POC meters and a Stat Profile Critical Care Xpress blood analyzer. The results were analyzed using the Bland-Altman method. The blood lactate values produced by the hospital grade POC meter and one of the commercially POC meters were in good agreement with the Critical Care Xpress blood analyzer. Other commercially available POC meters produced acceptable agreement.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17904887     DOI: 10.1016/j.jfms.2007.07.002

Source DB:  PubMed          Journal:  J Feline Med Surg        ISSN: 1098-612X            Impact factor:   2.015


  5 in total

1.  Point-of-care lactate and creatinine analysis for sick obstetric patients at Queen Elizabeth Central Hospital in Blantyre, Malawi: A feasibility study.

Authors:  S A Glasmacher; P Bonongwe; W Stones
Journal:  Malawi Med J       Date:  2016-03       Impact factor: 0.875

2.  Effect of Dexamethasone on Resting Blood Lactate Concentrations in Horses.

Authors:  K Mizen; J Woodman; S R Boysen; C Wagg; P Greco-Otto; R Léguillette; M-F Roy
Journal:  J Vet Intern Med       Date:  2016-12-25       Impact factor: 3.333

3.  A Flexible Dual-Analyte Electrochemical Biosensor for Salivary Glucose and Lactate Detection.

Authors:  Mingyang Liu; Muqun Yang; Muxue Wang; Han Wang; Jing Cheng
Journal:  Biosensors (Basel)       Date:  2022-03-31

4.  Use of portable blood physiology point-of-care devices for basic and applied research on vertebrates: a review.

Authors:  Lauren J Stoot; Nicholas A Cairns; Felicia Cull; Jessica J Taylor; Jennifer D Jeffrey; Félix Morin; John W Mandelman; Timothy D Clark; Steven J Cooke
Journal:  Conserv Physiol       Date:  2014-04-04       Impact factor: 3.079

5.  Development and evaluation of three mortality prediction indices for cold-stunned Kemp's ridley sea turtles (Lepidochelys kempii).

Authors:  N I Stacy; C J Innis; J A Hernandez
Journal:  Conserv Physiol       Date:  2013-04-19       Impact factor: 3.079

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.