Quality assurance of image-guidance technologies.

Jean-Pierre Bissonnette1.   

Abstract

The introduction of image-guided radiotherapy systems (IGS) allows improved management of geometric variations in patient setup and internal organ motion. Commercially available technologies, based on ultrasound, projection radiography, or cone-beam CT, have been widely adopted in radiation therapy. All rely on the comparison of daily images with reference images of the patient anatomy to ensure coincidence of the treatment and planned isocenters. This article reviews how IGS hardware and software are commissioned for clinical release and what quality control checks are required to ensure consistent and reproducible geometric accuracy. As image guidance significantly modifies conventional radiotherapy processes, recommendations and potential issues are discussed to facilitate the introduction of image guidance into the clinical environment.

Entities:  

Mesh:

Year:  2007        PMID: 17903705     DOI: 10.1016/j.semradonc.2007.07.002

Source DB:  PubMed          Journal:  Semin Radiat Oncol        ISSN: 1053-4296            Impact factor:   5.934


  8 in total

Review 1.  A review of image-guided radiotherapy.

Authors:  George T Y Chen; Gregory C Sharp; Shinichiro Mori
Journal:  Radiol Phys Technol       Date:  2008-12-16

2.  Assessment and evaluation of MV image guidance system performance in radiotherapy.

Authors:  Nithya Kanakavelu; E James Jebaseelan Samuel
Journal:  Rep Pract Oncol Radiother       Date:  2015-02-07

3.  Long-term stability and mechanical characteristics of kV digital imaging system for proton radiotherapy.

Authors:  Mingyao Zhu; Thomas Botticello; Hsiao-Ming Lu; Brian Winey
Journal:  Med Phys       Date:  2014-04       Impact factor: 4.071

4.  Evaluation of the truebeam machine performance check (MPC) geometric checks for daily IGRT geometric accuracy quality assurance.

Authors:  Michael P Barnes; Peter B Greer
Journal:  J Appl Clin Med Phys       Date:  2017-03-22       Impact factor: 2.102

5.  Automated quality assurance for image-guided radiation therapy.

Authors:  Eduard Schreibmann; Eric Elder; Tim Fox
Journal:  J Appl Clin Med Phys       Date:  2009-01-27       Impact factor: 2.102

6.  Accuracy of automatic couch corrections with on-line volumetric imaging.

Authors:  Winnie Li; Douglas J Moseley; Tony Manfredi; David A Jaffray
Journal:  J Appl Clin Med Phys       Date:  2009-10-07       Impact factor: 2.102

7.  Evaluation of IsoCal geometric calibration system for Varian linacs equipped with on-board imager and electronic portal imaging device imaging systems.

Authors:  Song Gao; Weiliang Du; Peter Balter; Peter Munro; Andrew Jeung
Journal:  J Appl Clin Med Phys       Date:  2014-05-08       Impact factor: 2.102

8.  A positioning QA procedure for 2D/2D (kV/MV) and 3D/3D (CT/CBCT) image matching for radiotherapy patient setup.

Authors:  Huaiqun Guan; Rabih Hammoud; Fang-Fang Yin
Journal:  J Appl Clin Med Phys       Date:  2009-10-06       Impact factor: 2.102

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.