Literature DB >> 17900597

Solid-phase extraction combined with dispersive liquid-liquid microextraction-ultra preconcentration of chlorophenols in aqueous samples.

Nazir Fattahi1, Soheila Samadi, Yaghoub Assadi, Mohammad Reza Milani Hosseini.   

Abstract

The solid-phase extraction (SPE) joined with the dispersive liquid-liquid microextraction (DLLME) has been developed as an ultra preconcentration technique for the determination of chlorophenols in water samples. Chlorophenols (CPs) were employed as model compounds to assess the extraction procedure and were determined by gas chromatography-electron-capture detection (GC-ECD). In solid-phase extraction-dispersive liquid-liquid microextraction (SPE-DLLME), CPs were adsorbed from a large volume of aqueous samples (100 mL) into 100 mg functionalized styrene-divinylbenzene polymer (PPL) sorbent. After the elution of the desired compounds from the sorbent by using acetone, DLLME technique was performed on the obtained solution. Some important extraction parameters, such as sample solution flow rate, breakthrough volume, sample pH, type and volume of the elution solvent as well as the salt addition, were studied and optimized. The new method (SPE-DLLME) provided an ultra enrichment factor (4390-17,870) for 19 CPs. The calibration graphs were linear in the range of 0.001-20 microg L(-1) and the limits of detection (LODs) ranged from 0.0005 to 0.1 microg L(-1). The relative standard deviations (RSDs, for 10.0 microg L(-1) of MCPs, 5.00 microg L(-1) of DCPs, 0.200 microg L(-1) of TCPs, 0.100 microg L(-1) of TeCPs and PCP) with and without the internal standard varied from 1.1 to 6.4% (n=7) and 2.5-9.7% (n=7), respectively. The relative recoveries of the well, tap and river water samples, spiked with different levels of CPs, were 71-110%, 73-115% and 88-121%, respectively.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17900597     DOI: 10.1016/j.chroma.2007.09.002

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  2 in total

1.  Liquid chromatography with post-column reagent addition of ammonia in methanol coupled to negative ion electrospray ionization tandem mass spectrometry for determination of phenoxyacid herbicides and their degradation products in surface water.

Authors:  Renata Raina; Michele L Etter
Journal:  Anal Chem Insights       Date:  2010-02-03

Review 2.  Methodologies for the extraction of phenolic compounds from environmental samples: new approaches.

Authors:  Cristina Mahugo Santana; Zoraida Sosa Ferrera; M Esther Torres Padrón; José Juan Santana Rodríguez
Journal:  Molecules       Date:  2009-01-09       Impact factor: 4.411

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.