Literature DB >> 17899602

Selective parity RARE imaging.

David G Norris1.   

Abstract

This work describes a novel method for rapid acquisition with relaxation enhancement (RARE)/fast spin-echo (FSE) imaging that removes the constraint of compliance with the Carr-Purcell-Meiboom-Gill (CPMG) condition. In a multiecho sequence, echoes with either odd or even parities are acquired. The refocusing angles are chosen using a recursive algorithm, so that the signal amplitude satisfies a predetermined modulation function. In the examples given in this article an exponential decay to a plateau is used. At each echo the echo parity that gives the desired signal amplitude for the minimum refocusing angle is selected. It is further shown that in the presence of an initial magnetization having an arbitrary phase distribution, the complex conjugate of the signal of one echo parity has to be taken and its k-space coordinates reversed. T(2) (*)-weighted images are presented and initial applications to diffusion-weighted imaging (DWI) and functional imaging shown.

Mesh:

Year:  2007        PMID: 17899602     DOI: 10.1002/mrm.21339

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  6 in total

1.  Body Diffusion Weighted Imaging Using Non-CPMG Fast Spin Echo.

Authors:  Eric K Gibbons; Patrick Le Roux; Shreyas S Vasanawala; John M Pauly; Adam B Kerr
Journal:  IEEE Trans Med Imaging       Date:  2016-10-27       Impact factor: 10.048

Review 2.  Diffusion-weighted breast MRI: Clinical applications and emerging techniques.

Authors:  Savannah C Partridge; Noam Nissan; Habib Rahbar; Averi E Kitsch; Eric E Sigmund
Journal:  J Magn Reson Imaging       Date:  2016-09-30       Impact factor: 4.813

Review 3.  New methods in diffusion-weighted and diffusion tensor imaging.

Authors:  Roland Bammer; Samantha J Holdsworth; Wouter B Veldhuis; Stefan T Skare
Journal:  Magn Reson Imaging Clin N Am       Date:  2009-05       Impact factor: 2.266

4.  BOLD fMRI using a modified HASTE sequence.

Authors:  Yongquan Ye; Yan Zhuo; Rong Xue; Xiaohong Joe Zhou
Journal:  Neuroimage       Date:  2009-07-28       Impact factor: 6.556

5.  A phase-cycled temperature-sensitive fast spin echo sequence with conductivity bias correction for monitoring of mild RF hyperthermia with PRFS.

Authors:  Mingming Wu; Hendrik T Mulder; Yuval Zur; Silke Lechner-Greite; Marion I Menzel; Margarethus M Paulides; Gerard C van Rhoon; Axel Haase
Journal:  MAGMA       Date:  2018-12-04       Impact factor: 2.310

6.  MRI-derived diffusion parameters in the human optic nerve and its surrounding sheath during head-down tilt.

Authors:  Darius A Gerlach; Karina Marshall-Goebel; Khader M Hasan; Larry A Kramer; Noam Alperin; Joern Rittweger
Journal:  NPJ Microgravity       Date:  2017-06-21       Impact factor: 4.415

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.