Literature DB >> 17897497

Effects of bur wear during implant site preparation: an in vitro study.

A Scarano1, F Carinci, A Quaranta, D Di Iorio, B Assenza, A Piattelli.   

Abstract

BACKGROUND: Few studies have investigated the influence of drilling on bone healing. After the drilling of bone and placement of dental implants a sequence begins of cellular and molecular events which represents a combined response of wound healing. The bone healing around dental implants is a complex phenomenon and influences the proliferation and differentiation of pre-osteoblasts into osteoblasts, together with the activation of periosteal and endosteal lining cells, and initiates the production and mineralization of osteoid matrix followed by the organization of the bone-implant interface. The objective of this study is to quantify the temperature changes in cortical bone and marrow spaces during implant site preparation in bovine rib bone. A total 10 harvested bovine ribs and 6 10.5 x 3.5 new drills for implant insertion with external irrigation (Bone System, Milano, Italy) were used in this study. The implant sites were prepared with 10 mm long drills at 500 rpm under abundant external irrigation with saline solution at 37 degrees C. Each drill was used for 10, 30, 60, 90 and 120 implant site preparations; each drill was then observed under SEM for evaluation of the damage of the cutting edge after 10, 30, 60, 90 and 120 preparations. There was an higher and statistically significant increase in the temperature in the cortical bone; this increase in temperature increases with the number of the times of drill use. The drill wear seemed to play a major role in heat production and could explain the observed increased temperature of the bone.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17897497     DOI: 10.1177/039463200702001s06

Source DB:  PubMed          Journal:  Int J Immunopathol Pharmacol        ISSN: 0394-6320            Impact factor:   3.219


  12 in total

Review 1.  Heat generated by dental implant drills during osteotomy-a review: heat generated by dental implant drills.

Authors:  Sunil Kumar Mishra; Ramesh Chowdhary
Journal:  J Indian Prosthodont Soc       Date:  2014-02-18

2.  Polymerization shrinkage and spherical glass mega fillers: effects on cuspal deflection.

Authors:  M Andreasi Bassi; S Serra; C Andrisani; S Lico; L Baggi; D Lauritano
Journal:  Oral Implantol (Rome)       Date:  2017-02-14

Review 3.  Surgical Drill Bit Design and Thermomechanical Damage in Bone Drilling: A Review.

Authors:  Mohd Faizal Ali Akhbar; Akmal Wani Sulong
Journal:  Ann Biomed Eng       Date:  2020-08-28       Impact factor: 3.934

4.  Ultrasound and analysis of the deformation patterns of the masseter muscle: comparing surgical anatomy, ultrasound and functional anatomy.

Authors:  A Busato; G Balconi; V Vismara; L Bertelè; G Garo; D DE Gregorio
Journal:  Oral Implantol (Rome)       Date:  2017-02-14

5.  Management and control of isotonic contraction generated stress: evaluation of masseter muscle deformation pattern by means of ecography.

Authors:  A Busato; G Balconi; V Vismara; L Bertelè; G Garo; D DE Gregorio
Journal:  Oral Implantol (Rome)       Date:  2017-02-14

6.  Influence of bone density and implant drill diameter on the resulting axial force and temperature development in implant burs and artificial bone: an in vitro study.

Authors:  Stephan Christian Möhlhenrich; Mustapha Abouridouane; Nicole Heussen; Ali Modabber; Fritz Klocke; Frank Hölzle
Journal:  Oral Maxillofac Surg       Date:  2015-11-20

Review 7.  Heat Development During Medical Drilling: Influencing Factors and Examination Methods - Overview and First Results.

Authors:  Ole Jung; Carolin Lindner; Sven Pantermehl; Mike Barbeck
Journal:  In Vivo       Date:  2021 Nov-Dec       Impact factor: 2.155

8.  In Vitro Study on Bone Heating during Drilling of the Implant Site: Material, Design and Wear of the Surgical Drill.

Authors:  Juan Carlos Bernabeu-Mira; Hilario Pellicer-Chover; Miguel Peñarrocha-Diago; David Peñarrocha-Oltra
Journal:  Materials (Basel)       Date:  2020-04-19       Impact factor: 3.623

9.  Comparison of peri-implant bone loss between conventional drilling with irrigation versus low-speed drilling without irrigation.

Authors:  H Pellicer-Chover; D Peñarrocha-Oltra; A Aloy-Prosper; J-C Sanchis-Gonzalez; M-A Peñarrocha-Diago; M Peñarrocha-Diago
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2017-11-01

10.  The Effects of Liquid Disinfection and Heat Sterilization Processes on Implant Drill Roughness: Energy Dispersion X-ray Microanalysis and Infrared Thermography.

Authors:  Antonio Scarano; Morena Petrini; Filiberto Mastrangelo; Sammy Noumbissi; Felice Lorusso
Journal:  J Clin Med       Date:  2020-04-04       Impact factor: 4.241