Literature DB >> 17893009

Accurate quantification of pulmonary artery diameter in patients with cyanotic congenital heart disease using multidetector-row computed tomography.

Yasunobu Hayabuchi1, Kazuhiro Mori, Tetsuya Kitagawa, Miki Inoue, Shoji Kagami.   

Abstract

BACKGROUND: The purpose of this study is to assess the feasibility of multidetector-row computed tomography (MDCT) for the quantitative evaluation of pulmonary artery morphology in children with congenital heart disease that is associated with reduced pulmonary blood flow.
METHODS: Quantification of measurements at the pulmonary artery annulus and right and left pulmonary arteries, and detection of stenoses exceeding 30% diameter reduction were evaluated independently on MDCT and conventional invasive angiography in 56 MDCT scans of 44 children. The diameters of the right and left pulmonary arteries were measured just proximal to the first branch and at the site of maximum stenosis.
RESULTS: There was an excellent correlation between MDCT and conventional pulmonary angiography in quantifying the diameter of the right and left pulmonary arteries (R2 = 0.85 and 0.82, respectively), although a systematic overestimation was observed on MDCT (bias 0.38 +/- 0.49 and 0.28 +/- 0.54 mm, respectively). The pulmonary artery annulus diameter on MDCT scans moderately correlated with the measurement on conventional angiograms (R2 = 0.48). Multidetector-row computed tomography correctly detected 15 of 16 pulmonary artery stenotic lesions that were detected on invasive angiography. There was an excellent correlation between MDCT and conventional angiograms with respect to evaluation of stenotic sites (R2 = 0.82).
CONCLUSIONS: Our findings showed a strong correlation of vessel diameter measurements between MDCT and invasive pulmonary angiography. This study demonstrates the feasibility of MDCT in assessing pulmonary artery size and morphology.

Entities:  

Mesh:

Year:  2007        PMID: 17893009     DOI: 10.1016/j.ahj.2007.06.004

Source DB:  PubMed          Journal:  Am Heart J        ISSN: 0002-8703            Impact factor:   4.749


  10 in total

1.  Assessment of modified Blalock-Taussig shunt in children with congenital heart disease using multidetector-row computed tomography.

Authors:  Manal Mohamed Helmy Nabo; Yasunobu Hayabuchi; Miki Inoue; Noriko Watanabe; Miho Sakata; Shoji Kagami
Journal:  Heart Vessels       Date:  2010-09-28       Impact factor: 2.037

2.  Evaluation of image quality and radiation dose of thoracic and coronary dual-source CT in 110 infants with congenital heart disease.

Authors:  Moez Ben Saad; Adela Rohnean; Anne Sigal-Cinqualbre; Ghazal Adler; Jean-Francois Paul
Journal:  Pediatr Radiol       Date:  2009-03-25

3.  Retrospective versus prospective ECG-gated dual-source CT in pediatric patients with congenital heart diseases: comparison of image quality and radiation dose.

Authors:  Kwang Nam Jin; Eun-Ah Park; Cheong-Il Shin; Whal Lee; Jin Wook Chung; Jae Hyung Park
Journal:  Int J Cardiovasc Imaging       Date:  2010-01-01       Impact factor: 2.357

4.  Comparison of 16-multidetector-row computed tomography and angiocardiography for evaluating the central pulmonary artery diameter and pulmonary artery index in children with congenital heart disease.

Authors:  Motoo Nakagawa; Masaki Hara; Hidekazu Oshima; Yuta Shibamoto; Kantaro Mizuno; Miki Asano
Journal:  Radiat Med       Date:  2008-08-03

5.  Tracheal compression due to an elongated aortic arch in patients with congenital heart disease: evaluation using multidetector-row CT.

Authors:  Noriko Watanabe; Yasunobu Hayabuchi; Miki Inoue; Miho Sakata; Manal Mohamed Helmy Nabo; Ryuji Nakagawa; Takahiko Saijo; Shoji Kagami
Journal:  Pediatr Radiol       Date:  2009-06-23

6.  Consideration of the Pathological Features of Pediatric Congenital Heart Diseases Which Are Ideally Suitable for Diagnosing With Multidetector-row CT.

Authors:  Yasunobu Hayabuchi; Miki Inoue; Noriko Watanabe; Miho Sakata; Tatsuya Ohnishi; Shoji Kagami
Journal:  Cardiol Res       Date:  2011-07-25

7.  Dual-source Computed Tomography for Evaluating Pulmonary Artery and Aorta in Pediatric Patients with Single Ventricle.

Authors:  Meng-Xi Yang; Zhi-Gang Yang; Yi Zhang; Ke Shi; Hua-Yan Xu; Kai-Yue Diao; Ying-Kun Guo
Journal:  Sci Rep       Date:  2017-10-17       Impact factor: 4.379

8.  Comparison of pulmonary artery dimensions in swine obtained from catheter angiography, multi-slice computed tomography, 3D-rotational angiography and phase-contrast magnetic resonance angiography.

Authors:  Ryan Pewowaruk; Klarka Mendrisova; Carolina Larrain; Christopher J Francois; Alejandro Roldán-Alzate; Luke Lamers
Journal:  Int J Cardiovasc Imaging       Date:  2020-10-09       Impact factor: 2.357

9.  Optimal Attenuation Threshold for Quantifying CT Pulmonary Vascular Volume Ratio.

Authors:  Hyun Woo Goo; Sang Hyub Park
Journal:  Korean J Radiol       Date:  2020-06       Impact factor: 3.500

10.  A Comparison of the Pulmonary Valve, Main Pulmonary Artery, and Branch Pulmonary Artery Measurements by Echocardiography and Computed Tomography Scan.

Authors:  Priyanka A Parikh; Binoy V Shah; Bhadra Trivedi; Viral B Patel; Shreya Desai; Somashekhar M Nimbalkar; Ajay G Phatak
Journal:  Cureus       Date:  2021-06-30
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.