Literature DB >> 17891034

Effect of changing indications and techniques on total hip resurfacing.

Michael A Mont1, Thorsten M Seyler, Slif D Ulrich, Paul E Beaule, Harold S Boyd, Michael J Grecula, Victor M Goldberg, William R Kennedy, David R Marker, Thomas P Schmalzried, Edward A Sparling, Thomas Parker Vail, Harlan C Amstutz.   

Abstract

Recently, improved metal-on-metal bearing technology has led to the reemergence of resurfacing as a reasonable option for total hip arthroplasty. During the course of a prospective multicenter FDA-IDE evaluation of metal-on-metal total hip resurfacings, we modified our indications and emphasized surgical technique where the femoral surface area was small due to femoral cysts and small component size. We assessed the influence of these changes on complication rates in the first cohort of 292 patients and the second of 724, and then compared these outcomes in the second cohort with historical reports of resurfacing. We had a minimum followup of 24 months (mean, 33 months; range, 24-60 months). After changes were made in the indications and technique, the overall complication rate decreased from 13.4% to 2.1% with the femoral neck fracture rate reduced from 7.2% to 0.8%. The outcomes of the second cohort compare with modern-day resurfacing devices and appear superior to historical results. The data suggest patients should be carefully selected and technique optimized to reduce complications. Long-term followup is required to see if these promising results will be maintained.

Entities:  

Mesh:

Year:  2007        PMID: 17891034     DOI: 10.1097/BLO.0b013e318159dd60

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  37 in total

1.  [Durom™ hip resurfacing. Short- to midterm clinical and radiological outcome].

Authors:  J Goronzy; M Stiehler; S Kirschner; K-P Günther
Journal:  Orthopade       Date:  2010-09       Impact factor: 1.087

Review 2.  Survival of hard-on-hard bearings in total hip arthroplasty: a systematic review.

Authors:  Michael G Zywiel; Siraj A Sayeed; Aaron J Johnson; Thomas P Schmalzried; Michael A Mont
Journal:  Clin Orthop Relat Res       Date:  2011-06       Impact factor: 4.176

3.  2011 Marshall Urist Young Investigator Award: when to release patients to high-impact activities after hip resurfacing.

Authors:  Katherine M Bedigrew; Erin L Ruh; Qin Zhang; John C Clohisy; Robert L Barrack; Ryan M Nunley
Journal:  Clin Orthop Relat Res       Date:  2011-10-18       Impact factor: 4.176

4.  A simple technique for alignment in total hip resurfacing arthroplasty: technical note and preliminary report.

Authors:  Manuel Villanueva-Martínez; Antonio Ríos-Luna; Angel Villamor-Pérez
Journal:  HSS J       Date:  2009-06-09

5.  2008 Otto Aufranc Award: component design and technique affect cement penetration in hip resurfacing.

Authors:  Paul E Beaulé; Wadih Y Matar; Philippe Poitras; Kevin Smit; Olivier May
Journal:  Clin Orthop Relat Res       Date:  2008-10-16       Impact factor: 4.176

6.  Component alignment in hip resurfacing using computer navigation.

Authors:  Chris Bailey; Rehan Gul; Mark Falworth; Steven Zadow; Roger Oakeshott
Journal:  Clin Orthop Relat Res       Date:  2008-10-30       Impact factor: 4.176

Review 7.  Surgical management of hip osteoarthritis.

Authors:  Rajiv Gandhi; Anthony V Perruccio; Nizar N Mahomed
Journal:  CMAJ       Date:  2013-10-21       Impact factor: 8.262

8.  Surface replacement is comparable to primary total hip arthroplasty.

Authors:  Mike S McGrath; David R Marker; Thorsten M Seyler; Slif D Ulrich; Michael A Mont
Journal:  Clin Orthop Relat Res       Date:  2008-09-16       Impact factor: 4.176

9.  Hip resurfacing data from national joint registries: what do they tell us? What do they not tell us?

Authors:  Kristoff Corten; Steven J MacDonald
Journal:  Clin Orthop Relat Res       Date:  2010-02       Impact factor: 4.176

10.  Use of patient-specific templates in hip resurfacing arthroplasty: experience from sixteen cases.

Authors:  Hao Du; Xiao-xiao Tian; Tong-sen Li; Jin-sheng Yang; Ke-han Li; Guo-xian Pei; Le Xie
Journal:  Int Orthop       Date:  2013-03-02       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.