Literature DB >> 17889275

Prostate planning treatment volume margin calculation based on the ExacTrac X-Ray 6D image-guided system: margins for various clinical implementations.

Sara Alonso-Arrizabalaga1, Luis Brualla González, Juan V Roselló Ferrando, Jorge Pastor Peidro, José López Torrecilla, Domingo Planes Meseguer, Trinidad García Hernández.   

Abstract

PURPOSE: To assess the prostate motion from day-to-day setup, as well as during irradiation time, to calculate planning target volume (PTV) margins. PTV margins differ depending on the clinical implementation of an image-guided system. Three cases were considered in this study: daily bony anatomy match, center of gravity of the implanted marker seeds calculated with a limited number of imaged days, and daily online correction based on implanted marker seeds. METHODS AND MATERIALS: A cohort of 30 nonrandomized patients and 1,330 pairs of stereoscopic kV images have been used to determine the prostate movement. The commercial image guided positioning tool employed was ExacTrac X-Ray 6D (BrainLAB AG, Feldkirchen, Germany).
RESULTS: Planning target volume margins such that a minimum of 95% of the prescribed dose covers the clinical target volume for 90% of the population are presented. PTV margins based on daily bony anatomy match, including intrafraction correction, would be 11.5, 13.5, and 4.5 mm in the anterior-posterior, superior-inferior, and right-left directions, respectively. This margin can be further reduced to 8.1, 8.6, and 4.8 mm (including intrafraction motion) if implanted marker seeds are used. Finally, daily on line correction based on marker seeds would result in the smallest of the studied margins: 4.7, 6.2, and 1.9 mm.
CONCLUSION: Planning target volume margins are dependent on the local clinical use of the image-guided RT system available in any radiotherapy department.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17889275     DOI: 10.1016/j.ijrobp.2007.06.063

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  8 in total

1.  Radiobiological comparison of two radiotherapy treatment techniques for high-risk prostate cancer.

Authors:  Trinitat García Hernández; Aurora Vicedo González; Jorge Pastor Peidro; Juan V Roselló Ferrando; Luis Brualla González; Domingo Granero Cabañero; José López Torrecilla
Journal:  Rep Pract Oncol Radiother       Date:  2013-02-08

2.  Residual translational and rotational errors after kV X-ray image-guided correction of prostate location using implanted fiducials.

Authors:  Reinhold Graf; Dirk Boehmer; Volker Budach; Peter Wust
Journal:  Strahlenther Onkol       Date:  2010-09-30       Impact factor: 3.621

3.  Couch and multileaf collimator tracking: A clinical feasibility study for pancreas and liver treatment.

Authors:  Lei Zhang; Thomas LoSasso; Pengpeng Zhang; Margie Hunt; Gig Mageras; Grace Tang
Journal:  Med Phys       Date:  2020-09-11       Impact factor: 4.071

4.  Uncertainty in patient set-up margin analysis in radiation therapy.

Authors:  Junji Suzuki; Kunihiko Tateoka; Katsumi Shima; Yuji Yaegashi; Kazunori Fujimoto; Yuichi Saitoh; Akihiro Nakata; Tadanori Abe; Takuya Nakazawa; Kouichi Sakata; Masato Hareyama
Journal:  J Radiat Res       Date:  2012-06-06       Impact factor: 2.724

5.  Assessment of interfractional prostate motion in patients immobilized in the prone position using a thermoplastic shell.

Authors:  Itaru Ikeda; Takashi Mizowaki; Yohei Sawada; Manabu Nakata; Yoshiki Norihisa; Masakazu Ogura; Masahiro Hiraoka
Journal:  J Radiat Res       Date:  2013-07-16       Impact factor: 2.724

6.  Simultaneous MV-kV imaging for intrafractional motion management during volumetric-modulated arc therapy delivery.

Authors:  Margie A Hunt; Mark Sonnick; Hai Pham; Rajesh Regmi; Jian-ping Xiong; Daniel Morf; Gig S Mageras; Michael Zelefsky; Pengpeng Zhang
Journal:  J Appl Clin Med Phys       Date:  2016-03-08       Impact factor: 2.102

7.  Study of ExacTrac X-ray 6D IGRT setup uncertainty for marker-based prostate IMRT treatment.

Authors:  Chengyu Shi; Adam Tazi; Deborah Xiangdong Fang; Christopher Iannuzzi
Journal:  J Appl Clin Med Phys       Date:  2012-05-10       Impact factor: 2.102

8.  Analysis of Motion-dependent Clinical Outcome of Tumor Tracking Stereotactic Body Radiotherapy for Prostate Cancer.

Authors:  Hoon Sik Choi; Ki Mun Kang; Bae Kwon Jeong; Jin Ho Song; Yun Hee Lee; In Bong Ha; Sung Chul Kam; Jeong Seok Hwa; Jae Seog Hyun; Jungmo Do; Dong Hyeok Jeong; Hojin Jeong
Journal:  J Korean Med Sci       Date:  2018-04-02       Impact factor: 2.153

  8 in total