Literature DB >> 17885192

Recent myocardial infarction: assessment with unenhanced T1-weighted MR imaging.

James W Goldfarb1, Sheeba Arnold, Jing Han.   

Abstract

The purpose of the study was to prospectively evaluate a T1-weighted technique for detection of myocardial edema resulting from recent myocardial infarction (MI) or intervention. This study was HIPAA compliant and institutional review board approved. Fifteen men and one woman (mean age, 57.8 years+/-11.5 [standard deviation]) were examined with T1-weighted magnetic resonance (MR) imaging and inversion-recovery cine pulse sequence in two groups, recent MI and chronic MI, and gave informed consent. T1 relaxation times of MI and adjacent myocardium were compared (Student t test and correlation analysis). In patients with recent MI, areas of myocardial edema were well depicted with T1-weighted MR imaging. T1 relaxation times of recent infarcts were longer than those of older MIs (925 msec+/-169 vs 551 msec+/-107, P<.001). From local edema, T1 relaxation time of infarcted myocardium is increased, may remain elevated for 2 months, and enables imaging with T1-weighted techniques. Copyright (c) RSNA, 2007.

Entities:  

Mesh:

Year:  2007        PMID: 17885192     DOI: 10.1148/radiol.2451061590

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  27 in total

1.  Myocardial perfusion imaging and infarct characterization using multidetector cardiac computed tomography.

Authors:  Gastón A Rodríguez-Granillo; Carlos A Ingino; Pedro Lylyk
Journal:  World J Cardiol       Date:  2010-07-21

2.  Determination of location, size, and transmurality of chronic myocardial infarction without exogenous contrast media by using cardiac magnetic resonance imaging at 3 T.

Authors:  Avinash Kali; Ivan Cokic; Richard L Q Tang; Hsin-Jung Yang; Behzad Sharif; Eduardo Marbán; Debiao Li; Daniel S Berman; Rohan Dharmakumar
Journal:  Circ Cardiovasc Imaging       Date:  2014-03-28       Impact factor: 7.792

3.  Simultaneous multislice cardiac magnetic resonance fingerprinting using low rank reconstruction.

Authors:  Jesse I Hamilton; Yun Jiang; Dan Ma; Yong Chen; Wei-Ching Lo; Mark Griswold; Nicole Seiberlich
Journal:  NMR Biomed       Date:  2018-12-18       Impact factor: 4.044

4.  Novel cardiac magnetic resonance biomarkers: native T1 and extracellular volume myocardial mapping.

Authors:  Paola Maria Cannaò; Luisa Altabella; Marcello Petrini; Marco Alì; Francesco Secchi; Francesco Sardanelli
Journal:  Eur Heart J Suppl       Date:  2016-04-29       Impact factor: 1.803

5.  Cardiac cine magnetic resonance fingerprinting for combined ejection fraction, T1 and T2 quantification.

Authors:  Jesse I Hamilton; Yun Jiang; Brendan Eck; Mark Griswold; Nicole Seiberlich
Journal:  NMR Biomed       Date:  2020-06-05       Impact factor: 4.044

Review 6.  Myocardial interstitial remodelling in non-ischaemic dilated cardiomyopathy: insights from cardiovascular magnetic resonance.

Authors:  Andrea Barison; Chrysanthos Grigoratos; Giancarlo Todiere; Giovanni Donato Aquaro
Journal:  Heart Fail Rev       Date:  2015-11       Impact factor: 4.214

7.  Myocardial edema as detected by pre-contrast T1 and T2 CMR delineates area at risk associated with acute myocardial infarction.

Authors:  Martin Ugander; Paul S Bagi; Abiola J Oki; Billy Chen; Li-Yueh Hsu; Anthony H Aletras; Saurabh Shah; Andreas Greiser; Peter Kellman; Andrew E Arai
Journal:  JACC Cardiovasc Imaging       Date:  2012-06

8.  Assessment of myocardium at risk with contrast enhanced steady-state free precession cine cardiovascular magnetic resonance compared to single-photon emission computed tomography.

Authors:  Peder Sörensson; Einar Heiberg; Nawsad Saleh; Frederic Bouvier; Kenneth Caidahl; Per Tornvall; Lars Rydén; John Pernow; Håkan Arheden
Journal:  J Cardiovasc Magn Reson       Date:  2010-04-30       Impact factor: 5.364

9.  MR fingerprinting for rapid quantification of myocardial T1 , T2 , and proton spin density.

Authors:  Jesse I Hamilton; Yun Jiang; Yong Chen; Dan Ma; Wei-Ching Lo; Mark Griswold; Nicole Seiberlich
Journal:  Magn Reson Med       Date:  2016-04-01       Impact factor: 4.668

10.  Improve myocardial T1 measurement in rats with a new regression model: application to myocardial infarction and beyond.

Authors:  Haosen Zhang; Qing Ye; Jie Zheng; Erik B Schelbert; T Kevin Hitchens; Chien Ho
Journal:  Magn Reson Med       Date:  2013-10-18       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.